Applications and Solutions for Environment & Energy

"NETZSCH is known worldwide as a specialist in the field of wastewater treatment and biogas technology. Our NEMO® progressing cavity pumps and TORNADO® rotary lobe pumps are global leaders in the field of wastewater treatment. However, we also support farmers and energy producers with our patented solutions in the renewable energies area, especially in terms of environmentally friendly biogas production."

Michael Groth
Business Field Manager Environmental & Energy


Pumps for Environment & Energy Industry


Applications in the fields of environment and energy can be covered with different pump systems. NETZSCH rotary lobeprogressing cavity pumps and multi screw pumps, also in combination with our macerators, always ensure the right solution for your process. NETZSCH advises independent and neutral, to find the best selection of pump you need for your applications.

Success Stories in the Environmental and Energy Sector

Extraction of saturated brine: Especially designed progressing cavity pump conveys spa water from a Glauber’s salt spring in Saxony

In September 2015, new 4,500 m² salt water thermal baths were opened in a spa town in Saxony that is steeped in tradition. They are fed from a highly-saturated Glauber’s salt spring. More...

Turning two into one: A water company needs one less unit thanks to FSIP® pump design

A water company in Northern Italy used two progressing cavity pumps of the NEMO® BY type in block construction design. One of them has being used to convey sludge into the centrifuge, while the second was permanently in standby mode. More...

Brazilian hydroelectric power stations rely in terms of implementing the energy turnaround on pump know-how from Germany

While Germany still faces many unsolved problems in terms of implementing the energy turnaround, they have moved significantly further on in South America. Of all the countries, the developing nation of Brazil is proving itself to be the role model when it comes to renewable energies. More...

Tripling service life in a waste water treatment plant: xLC® stator adjustment system permits situation-specific adaptation on NEMO® progressing cavity pump

The thickened sludge of a waste water treatment plant should be boosted into an intermediate tank. “The solids content is more than eight percent, so that the wear caused by the medium is expected to be very high”, says the head of the purification waste water treatment plant. More...


NEMO® BP hopper-shaped progressing cavity pump with aBP-bridge breaker prevent the constructions stop

There are two aspects of wastewater treatment plants at Celle (Germany) which have a direct use: in addition to cleaning waste water, the sewage sludge which arises with the nutrients it contains can be used later as manure in agriculture. More...

Low-wear conveyance of industrial waste water: Robust TORNADO® rotary lobe pumps make water treatment easier

Used service water from industrial processes is one of the most problematic types of waste water due to its composition, which is often very demanding for conveying systems. In order to enable problem-free treatment, the T.Envi® is designed for a long service life with minimum wear. More...

Reliable sludge removal for water jet cutting: Robust rotary lobe pump even pumps highly abrasive residual water

Cutting systems, which are based on high-pressure water jets and do not alter the material structure through their energy input like lasers do, are establishing themselves in more and more area. A cutting aid, an abrasive, is mixed into the water to increase cutting performance. More...

Biogas systems as top exports: German pump technology proves successful thanks to high mixing performance and robustness in bioreactors worldwide

The boom of environmentally friendly power and heat generation from renewable biomass continues. Especially countries such as the UK, France, Japan or the US discovered the advantages of renewable energies, primarily the use of biogas. More...

NEMO® BT immersible pump conveying beet pulp straight from the lagoon with low material wear

Beets, particularly sugar beets and specially-bred energy beets, are becoming more and more popular. The storage of the beets in silos or silage tubes is complicated and expensive. Collecting beet pulp in foil-lined reservoirs represents a comparatively simple and cost-effective alternative to this. More...

Hydraulics and lubrication for turbines weighing many tonnes: Brazilian hydroelectric power stations rely on pump know-how from Germany

Responsible for the environment and climate change, renewable energies are becoming increasingly important. Therefore, where the prerequisites are met, more and more hydroelectric power plants are being connected to the grid. More...

Operating small biogas plants efficiently: Special feed and homogenisation technology saves power and substrate

The reason for the slowdown of the large biogas boom in Germany were the reductions in subsidies and above all changes in aid made by the amendment to the German Renewable Energies Act (EEG). More...

Robust pumps enable a range of substrates to be conveyed, from liquid manure to food waste

Biogas is in high demand as a source of energy for power and heat generation. Systems that not only process crops specifically grown for power and heat generation, but also use otherwise useless bio waste, are excellent for the environment and are highly economical. More...


Products

NEMO® Pump BY

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

NEMO® BO/BS Pump with Hopper in Block Construction and Flanged Drive

The NEMO® BO/BS progressing cavity pump with square/rectangular hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance.

TORNADO® T1 Classic Rotary Lobe Pump

The TORNADO® T1 rotary lobe pump with its proven quality is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

NEMO® SY Industrial Construction in Bearing Block Design with Free Shaft Extension

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

NEMO® B.Max Mixing Pump

The NEMO® B.Max is setting new standards with its maximum mixing and conveying capabilities for biosubstrates.

M-Ovas® Grinding System

NETZSCH M-Ovas® grinding systems can be used wherever it is essential that solid matter in fluids be broken down reliably to ensure the prevention of pipe clogging and damage to downstream equipment.

NEMO® BP Hopper Pump with Feeding Screw and Bridge Breaking Paddle or aBP-Module

For highly viscous, compacted and crumbly substances that have a tendency to bridge, the NEMO® BP is the optimal solution. The NEMO® BP can be used in nearly all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance with dosing in proportion to rotation speed.

NEMO® BF Progressing Cavity Pump with Hopper and Feeding Screw

The NEMO® BF is used in all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance with dosing in proportion to rotation speed. It is employed primarily for highly viscous, compacted and crumbly substances that do not have a tendency to bridge.

N.Mac® - Double Shaft Grinder

Capable of fragmenting large and solid particles, the N.Mac® double shaft grinder is the ideal equipment to suit different applications.

NEMO® C.Pro Dosing Pump

The NEMO® N-Ipos CY C.Pro dosing pump is a fully synthetic pump for the precise dosing of a great variety of chemicals in environmental technology and the chemical industry. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation conveyance and dosing of aggressive or non-aggressive chemicals.

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

NOTOS® Multi Screw Pump

The NOTOS® family has superior quality standards to meet the highest level requirements from our customers. The pumps are designed to work with low to high lubricant fluids, low to high viscosity, shear sensitive and/or chemically agressive media.

more information