Conveying of Media in Potentially Explosive Atmospheres:

NETZSCH NOTOS® Multi Screw Pumps are ATEX-Certified

NETZSCH's NOTOS® multi screw pumps are ATEX certified and can therefore safely convey media in potentially explosive atmospheres.

Numerous companies have explosive areas, we have the right pump solution. 

Look behind the scenes

The Directive 2014/34/EU defines the marketing and provision of equipment and protective systems in potentially explosive atmospheres. If a product is proven to meet these requirements, no EU member state can hinder or prohibit market entry or order a recall.

Challenge accepted

According to the ATEX Directive, all equipment and products used in potentially explosive atmospheres require safety information beyond the instructions for use. These must be in the respective local language and include all information required for intended use.

Excellently solved

The German Institute for Sicherheitstechnik confirmed that NOTOS® multi screw pumps meet the requirements of explosion groups IIB and IIC (and therefore also explosion groups IIA, IIB and IIC).

NOTOS® multi screw pump 2NS, 3NS und 4NS

  • Medium: Media with low to highly lubricating liquids with low to high viscosity as well as shaker-sensitive or chemically aggressive media.
  • Throughput volume: Until 1500 m³/h
  • Viscosities: Until 200.000 cSt
  • Explosion groups: IIB and IIC (and therefore also explosion groups IIA, IIB, IIC)

ATEX Certificate

The different geometries of the three pump series are optimized for media with a wide variety of characteristics.

You may also be interested in:

 

 

NEMO® SY Industrial Construction in Bearing Block Design with Free Shaft Extension

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

NEMO® Pump BY

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

NEMO BO/SO Hopper Pump with integrated cutting device

The NEMO® BO/SO progressing cavity pump with hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to  provide continuous, pressure-stable, gentle and low-pulsation conveyance.

TORNADO® T.Sano® Rotary Lobe Pump in New Design

The new design of the TORNADO® T.Sano® rotary lobe pump plain has a completely smooth housing in comparison to the standard T.Sano®, which attracts barely any dirt or dust.  The whole T.Sano® series are EHEDG-certified.