Tank Truck Emptying in the Chemical Industry:

The TORNADO® T.Proc® in All-Metal Design Empties without Interruption

Emptying tankers can cause problems for many pumping processes.      

Look behind the scenes

The difficulties involved are air pockets which cannot be avoided when attaching a pipe. The gas bubbles initially lead to reduced performance and irregular running until the product flow stalls as the gas inflow further increases.

Challenge accepted

The product flow used to stall again and again during the emptying of the surfactant with the centrifugal pump that was used before. The centrifugal pump was intended to convey the basic material of the detergent from a road tanker to the company's production facility. However, problems arose as early as the suction phase: air which got into the pipe during connection of the tank formed air pockets in the medium. This led to slumps in performance and also to repeated stalling of the product flow. The pump kept on breaking down and had to be recommissioned, involving a great deal of effort from the personnel. Tanker drivers were often obliged to suffer a long unscheduled wait until the tank was empty, which meant high additional costs for hazardous goods carriers who have to adhere strictly to driving and rest times.    

Excellently solved

The surfactant being conveyed was diluted with a solvent in this application. Most plastics are not resistant to solvents and elastomer swells in contact with them and impairs pump performance. For this reason, the all-metal model of the T.Proc® made of stainless steel was installed. This type of TORNADO® rotary lobe pump enables to guarantee a long service life for all parts that come into contact with the product. A special universally usable elastomer was used for the seals which has high chemical and temperature resistance due to its composition. As the pump operates in an area which is designated as an explosion protection area 1, the pump must not run dry under any circumstances. For this reason, both pressure and dry running protection were integrated so that the pump automatically switches off in the event of a fault. The positive displacement pump has now been running trouble-free since the end of October 2013 and conveying 15 to 20 m³ of surfactant per hour at a pressure of 4 bar.

Meanwhile, there is no longer need for supervisory staff during the emptying of the tanker thanks to this high level of reliability and drivers can easily start the process themselves and complete it within the scheduled time frame. Additional costs for waiting times, production downtimes and the staff effort involved in recommissioning the centrifugal pump are a thing of the past.

Technical Data

Technical Data

NETZSCH TORNADO® T.Proc rotary lobe pump
MediumTenside
Throughput volume15 to 20m³/h
Pressure4 bar
ViscosityUp to 50.000 cP

Products

Products

The NETZSCH TORNADO® Mobile

A TORNADO® rotary lobe pump fastened onto a mobile base – this is the NETZSCH TORNADO® Mobile. The concept of mounting the equipment onto a car or truck trailer makes it possible to pump large quantities of fluids with solid content, wastewater and slurries at the most unusual of sites.

NETZSCH 1C Dosing Systems

In order to be able to offer you a complete dosing solution, our product line is supplemented by the following dosing components: Cartridge Discharge, Buffer Storage and 2C-Mixing Head.

NEMO® SY Industrial Construction in Bearing Block Design with Free Shaft Extension

The NEMO® SY Progressing Cavity Pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

NETZSCH Barrel Emptying Pumps

We’ll get the very last of it out for you!

NEMO® Pump BY

NEMO® BY Progressing Cavity Pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

NEMO® Dispensers

The highest level of precision in dosing and reproducibility.


Literature

Literature