NEMO® BF with Feeding Screw

NEMO® BF Hopper-Shaped Pump with Feeding Screw

Solution for highly viscous and crumbly substances that do not tend to bridge-building

The NEMO® BF is used in all branches of industry for continuous, pressure-stable, gentle and low-pulsation conveyance as well as for dosing in proportion to speed, especially of highly viscous, compacted and crumbly media that do not tend to bridge.

For optimum product feed into the conveying elements, the pump housing is designed with an enlarged, rectangular feed hopper and conical force-feed chamber as well as a special coupling rod with patented, positioned conveying screw. This also ensures the smooth conveying of solids containing shear-sensitive, abrasive, adhesive, thixotropic or dilatant as well as lubricating and non-lubricating materials. The NEMO® BF is particularly compact and economical in block construction with flanged drive.

Get a personalized offer now!

NEMO® BF with Feeding Screw

1 Rotor
In corrosion-resistant designs up to the rotor with wear-resistant coating.

2 Stator
Vulcanized into the tube with sealing on both sides in a variety of elastomers, plastics and metals. Stator inlet with hopper-shaped opening for improved feed of the product into the conveying chamber.

3 Drive chain
Drive and connecting shaft with a coupling rod with patented, horizontally positioned feeding screw for optimal feed into the conveying elements and two gimbal joints for the transmission of power from the drive to the rotor.

4 Shaft seals
Standard with single-acting, bi-directional, wear-resistant mechanical seal. Upon request, with single- or double-acting mechanical seals of varied designs and from various manufacturers, cartridge and special seals as well as packed glands.

5 Suction and discharge housing
Pump housing with enlarged rectangular hopper and conical force-feed chamber. The hopper dimensions can be adjusted to the individual application case. Flange and threaded connections in accordance with DIN and international standards. Materials in steel, chrome-nickel-steel rubberized; also special materials upon request.

6 Block construction
The drive is flanged directly to the lantern of the pump, resulting in compact dimensions, low total weight, constant axial heights irrespective of the construction type and size of the drive, and ease of maintenance and serviceability as well as high efficiency.

Size*

Pressure max.

(bar)

Capacity min.

(m³/h)

Capacity max.

(m³/h)

Speed

(rpm)

NM045 BF

 

 

 

 

 

36

 

 

 

 

 

0,2

 

 

 

 

 

60

 

 

 

 

 

up to 120

NM053 BF
NM063 BF
NM076 BF
NM090 BF
NM105 BF

*Further sizes and technical data on request.

  • Gentle product conveyance
  • Pump connections according to national and international standards, as well as in special design
  • Easy serviceability
  • Variable, modular construction system
  • Wide range of materials
  • Robust and compact block design
  • The right joint for every application
  • Mechanical seal as standard, other seals optional

You may also be interested in:

NEMO® BO/BS Pump With Hopper in Block Construction

The NEMO® BO/BS progressing cavity pump with square/rectangular hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® BF Hopper-Shaped Progressing Cavity Pump With aBP-Module®

The NEMO® BF hopper-shaped progressing cavity pump with aBP-Module® to prevent bridging is used in all branches of industry for continuous, pressure-stable, gentle and low-pulsation conveyance as well as dosing in proportion to speed, especially for highly viscous, compacted and crumbly media.

NEMO® B.Max Mixing Pump in Block Design

The NEMO® B.Max is setting new standards with its maximum mixing and conveying capabilities for biosubstrates.

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.