Special Base Frame for Reagent Pumps Reduces Maintenance:

Pump Technology Enhances Precision and Reliability in Copper Preparation Plant

An individually adapted special frame for reagent pumps ensures significantly reduced maintenance requirements in a copper processing plant in Zambia. 

In addition, the racks allow various adaptation options for the most diverse challenges. 

Look behind the scenes

Until January 2017, a copper beneficiation plant in Zambia was using pumps from six different manufacturers. Attributable to the large number of different models, this resulted in a steadily growing inventory of similar spare parts and maintenance procedures. Thereby, the effort and costs for necessary maintenance of the pumps were constantly increasing as a result. Following a thorough review of the reliability and service life of its pumps, the plant operator decided to simplify its spare parts inventory and maintenance - and only use pumps from a single supplier. NETZSCH, represented by its subsidiary in South Africa, was chosen for the reliability of its pumps. The Zambian company replaced 36 pumps for polymer applications and saved 1 million dollars by reducing its spare parts inventory as well. Its reagent pumps were then also optimised, as the existing solution could not provide the required capacity or achieve the necessary precision and reliability.   

Challenge accepted

Once the polymer pumps had been successfully standardised, NETZSCH was also asked to prepare possible ways to optimise the reagent pumps on site. The pumps that had been originally installed for this application were not delivering the required capacity. They also lacked the accuracy that was needed and were not reliable. "A special solution was necessary, because the pumps had to be attached to the floatation cells above and it proved difficult and time-consuming to make the necessary changes on site", explains Roger Willis, the business field manager of mining. The flotation cells are three storeys high, so changes would have meant working at height and in restricted space and would have required official permits for hot work. The new equipment would also have had to have been safely transported up to the cells first.  

Excellently solved 

"Instead, we recommended a plug & play system preassembled on a base frame", says Willis. This allowed the operator of the treatment plant to remove all the existing equipment and simply bring the frame into position. This avoided extensive welding work and production on site or at height on the cells. The system had to be specially made for the application. As the space was limited, NETZSCH came up with a particularly compact frame design. The three single frames with space for two pumps each, including central distribution pipes, seal support system and lowering pipes, are designed as a modular system. They can be easily combined, because the product intake and outflow lines and the distribution pipes of the mechanical seal support system can be easily connected.

The frame can also be used in temporary installations. They are fitted with forklift guides and crane attachment hooks, so chemical can be fed straight from an IBC tank to the pumps.   "Installing new frames meant the operator could rationalise its spare parts inventory for this application as well and increase plant availability", says Willis. "This complete solution also gave the customer the option of not contracting with anyone else to simplify execution of the project."  The frames designed by NETZSCH have a lot of potential for adaptation too. "We can install waste containers above the pumps and put in flow controllers, pressure monitoring systems and local control unit", explains Willis.

You may also be interested in:

NEMO® SY – Pompe industrielle à palier avec bout d’arbre nu

La pompe à vis excentrée NEMO® SY est utilisée à travers le monde pour des applications exigeantes dans tous les secteurs industriels. Dans sa version à palier, la pompe peut être entraînée par n'importe quel type d'entraînement en le raccordant à son arbre nu, même les plus spécifiques tels que des servomoteurs, des moteurs diesel ou des entraînements hydrauliques.

NEMO® BY Block Pump in Industrial Design

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

Pompe doseuse NEMO® C.Pro

La pompe doseuse NEMO® N-Ipos CY C.Pro est une pompe entièrement conçue en matière plastique pour le dosage précis de produits chimiques dans le domaine de l'environnement et de l'industrie chimique. Cette exécution tout-plastique résistante aux agressions chimiques, est en effet particulièrement adaptée pour véhiculer et doser, avec ménagement et sans pulsation, les produits réputés difficiles que sont les produits chimiques, qu'ils soient agressifs ou pas.

Pompe à lobes TORNADO® T2

Les pompes à lobes NETZSCH TORNADO® sont des équipements à usage universel. Elles trouvent leur application dans l'assainissement et l'industrie chimique pour le pompage et le dosage continu, sans pulsation et sans destruction de toute fluide.