Safe Delivery of Ammonium Nitrate Emulsion:

NEMO® SY Progressing Cavity Pump Accelerates Delivery to Mining Customers

Due to their significantly longer service life, NEMO® progressing cavity pumps accelerate the supply of a ready-to-use ammonium nitrate emulsion to mining operations and increase the service life of the unit as well as the throughput capacity of the entire system. 

High safety during the transport of “volatile” explosives is one of the challenges in mining.

Look behind the scenes

Safety in mining and at construction sites where explosives are used was a problem for a long time, because the storage and transport of “volatile” explosives always constitute an enormous risk. In order to reduce the danger and achieve a better explosive performance, there has for some time been greater use of pumpable emulsion explosives.  

Challenge accepted 

A global explosives manufacturer had used a progressing cavity pump to fill the storage silos with the ready-to-use ammonium nitrate emulsion. However, the pump did not provide the required level of performance and delayed the supplying of the mines and customers due to regular breakdowns. The pin joint could not withstand the torque nor the deflection on the coupling rod and therefore often failed. The shortness of the coupling rod increased the angle which the joint had to compensate. That not only increased the stress on the joint itself, but also the dynamic load on its seal system. The lubricating effect of the lubricant used for the pin joint was not sufficient either. As a result, the pump was constantly breaking down. Since the pump had a crucial role to play in the process chain, every breakdown led to costly delivery delays.  

Excellently solved

In order to increase the service life for the application and the throughput rate of the whole system, the emulsion manufacturer searched for a more reliable pump with a larger capacity and found NETZSCH. Mining specialist Tyron Adam proposed a NEMO® progressing cavity pump for the job. It is ideally suited for ammonium nitrate emulsion, because consistency and viscosity of the medium are insignificant in terms of the product flow. At this application the NEMO® progressing cavity pump was also fitted with the NEMO® V-pin joint, that is filled with oil in order to achieve a long service life. To increase the lifetime of the pin joint even in the toughest operating conditions, it also has hardened bushes. These are pressed into the boreholes of the coupling rod and the rotor head or drive shaft head and can be particularly easily replaced during maintenance work.

For reasons of safety, the pump was not fitted with a single mechanical seal with pressure-free quenching: To further increase process reliability and minimise risk of product crystalizing between seal faces, a double-acting ASSEAL mechanical seal with thermosiphon vessels was used. In addition, the installation of a variable speed control enables the manufacturer to implement a control concept which provides for adjusting the conveying speed of the pump to the specific quantity of emulsion which is available for filling the storage tanks. This process optimization allows a considerable reduction of the number of pump starts during a shift, which significantly increases the service life of the pump. Since March 2013 the NEMO® pump has been running trouble-free.

NEMO® SY progressing cavity pump

  • Medium: Ammonium nitrate emulsion
  • Temperature: 50 °C
  • Viscosity: 18.000 to 22.000 mPas
  • Rotations speed: 189 rpm
  • Throughput volume: 48 m³/h
  • Pressure: 9 bar

You may also be interested in:

NEMO® SY Industrial Construction in Bearing Block Design

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

NEMO® BY Block Pump in Industrial Design

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

NEMO® C.Pro Dosing Pump Made of Synthetic Materials

The NEMO® C.Pro dosing pump is a fully synthetic pump for the precise dosing of a great variety of chemicals in environmental technology and the chemical industry. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation conveyance and dosing of aggressive or non-aggressive chemicals.

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.