NETZSCH Pump Solutions in the Fields of Environment and Energy

We find and develop the perfect positive displacement pump for your individual application

Michael Groth Business Field Manager Environmental & Energy

"NETZSCH is known worldwide as a specialist in the field of wastewater treatment and biogas technology. Our NEMO® progressing cavity pumps and TORNADO® rotary lobe pumps are global leaders in the field of wastewater treatment. However, we also support farmers and energy producers with our patented solutions in the renewable energies area, especially in terms of environmentally friendly biogas production."

Michael Groth
Business Field Manager Environmental & Energy


As a global specialist for pumps and systems in the field of environment and energy, NETZSCH offers you solutions individually tailored to your requirements. The satisfaction of our customers is always our top priority.

Whether for wastewater treatment, lubrication of hydraulic pumps, sludge pumping in sewage treatment plants or for a wide variety of applications in the field of biogas, we support you with our patented solutions. We promise you Proven Excellence - outstanding performance in all areas. In the environment and energy business area, the various pump systems cover almost all applications. TORNADO® rotary lobe pumps, NEMO® progressing cavity pumps and NOTOS® multi screw pumps, also in combination with our grinding systems, guarantee you the optimised solution for your process.

Leading supplier in the field of positive displacement pumps

"NETZSCH is known worldwide as a specialist in the field of wastewater treatment and biogas technology. Our NEMO® progressing cavity pumps and TORNADO® rotary lobe pumps are global leaders in the field of wastewater treatment”, says Michael Groth, business unit manager environment and energy.

We provide independent and unbiased advice to help you find the optimal positive displacement pump for your applications. NETZSCH develops a customised as well as a sophisticated solution for your request on a global level.

Low-wear pumping of highly abrasive wastewater in industry

With our TORNADO® T.Envi® rotary lobe pump, you can even convey industrial wastewater with high solids content and low wear. Despite the high abrasiveness, the design of the pump ensures a particularly long service life, for example, when desludging the wastewater during water jet cutting. In this way, the rotary lobe pump makes it easier for you to treat industrial wastewater. Due to the long service life and minimal wear, your maintenance requirements are extremely low despite the abrasive medium. This is made possible by the particularly innovative material mix of the TORNADO® T.Envi®.

Low-maintenance conveyance of wide variety of substrates in the biogas sector

High mixing performance and low material wear despite heavy loads play a crucial role in the biogas sector. The space-saving NEMO® progressing cavity pumps convey biogas reliably and without time-consuming maintenance work. Whether you have a small or large biogas plant, with the versatile progressing cavity pumps, you can convey a wide variety of substrates such as biomass or slurry over long distances and gradients without any problems. The innovative NEMO® B.Max progressing cavity pump offers you both high mixing performance and robustness. This ensures a continuous feed to the fermenter. At the same time, the NEMO® BT immersible pump enables you to convey highly viscous slurry from a foil earth tank. In addition, the pumps have an extremely long service life. In this way, you keep material wear low despite the high load. Furthermore, the efficient pump design requires very little power, which, together with the long service life and long maintenance intervals, results in low total cost of ownership.

Transport of clarified and thickened sludge for water treatment in sewage treatment plants

For water treatment in a sewage treatment plant, NEMO® progressing cavity pumps in FSIP® design with xLC® stator adjustment system reliably convey even abrasive sewage or thickened sludge. In addition, the special design of the pump allows you to extend its service life significantly. This saves you time and money. Thanks to the xLC® unit, you can compensate for stator and rotor wear without having to replace pump parts. If the sewage sludge is particularly firm, the NEMO® BF progressing cavity pump with aBP-Module® ensures uninterrupted loading. Thanks to the innovative design, you thus prevent a plant standstill.

Constant lubrication and hydraulic pump for turbines and aggregates

NOTOS® multi screw pumps guarantee you constant hydraulics and lubrication for turbines weighing several tons. Multi screw pumps can generate particularly high pressure. This allows you to react flexibly to changes in the amount of water produced, for example, when generating energy in a hydroelectric power plant. In this way, you prevent possible damage caused by spinning when the torque on the generator shaft drops.

Gentle pumping of spa water with a high brine content

NEMO® progressing cavity pumps are used for gentle and efficient pumping of spa water with a high brine content, for example, in spas. Thanks to the innovative heating jacket, the brine can be heated in the process. This allows you to increase the salt content in the water significantly. A downhole system initially developed for pumping in oil fields has been optimally adapted for pumping the unique fluid to the surface.

Success stories from the fields of environment and energy

NEMO® Progressing Cavity Pump Conveys Healing Water

Extraction of saturated brine: Especially designed progressing cavity pump conveys spa water from a Glauber’s salt spring in Saxony

In September 2015, new 4,500 m² salt water thermal baths were opened in a spa town in Saxony that is steeped in tradition. They are fed from a highly-saturated Glauber’s salt spring. More...

NEMO® Progressing Cavity Pump with FSIP® Ensures Uninterrupted Loading

Turning two into one: A water company needs one less unit thanks to FSIP® pump design

A water company in Northern Italy used two progressing cavity pumps of the NEMO® BY type in block construction design. One of them has being used to convey sludge into the centrifuge, while the second was permanently in standby mode. More...

NEMO® Progressing Cavity Pump with xLC® Stator and FSIP® Delivers Reliably

Tripling service life in a waste water treatment plant: xLC® stator adjustment system permits situation-specific adaptation on NEMO® progressing cavity pump

The thickened sludge of a waste water treatment plant should be boosted into an intermediate tank. “The solids content is more than eight percent, so that the wear caused by the medium is expected to be very high”, says the head of the purification waste water treatment plant. More...

NEMO® BP Progressing Cavity Pump with aBP-Module® Prevents System Downtime

NEMO® BP hopper-shaped progressing cavity pump with aBP-bridge breaker prevent the constructions stop

There are two aspects of wastewater treatment plants at Celle (Germany) which have a direct use: in addition to cleaning waste water, the sewage sludge which arises with the nutrients it contains can be used later as manure in agriculture. More...

TORNADO® T.Envi® Rotary Lobe Pump Facilitates Industrial Wastewater

Low-wear conveyance of industrial waste water: Robust TORNADO® rotary lobe pumps make water treatment easier

Used service water from industrial processes is one of the most problematic types of waste water due to its composition, which is often very demanding for conveying systems. In order to enable problem-free treatment, the T.Envi® is designed for a long service life with minimum wear. More...

Rotary Lobe Pumps Convey even Highly Abrasive Residual Water

Reliable sludge removal for water jet cutting: Robust rotary lobe pump even pumps highly abrasive residual water

Cutting systems, which are based on high-pressure water jets and do not alter the material structure through their energy input like lasers do, are establishing themselves in more and more area. A cutting aid, an abrasive, is mixed into the water to increase cutting performance. More...

NEMO® B.Max Progressing Cavity Pump Convinces through its Robustness

Biogas systems as top exports: German pump technology proves successful thanks to high mixing performance and robustness in bioreactors worldwide

The boom of environmentally friendly power and heat generation from renewable biomass continues. Especially countries such as the UK, France, Japan or the US discovered the advantages of renewable energies, primarily the use of biogas. More...

Low Material Wear in spite of High Loads with the NEMO® BT Immersible Pump

NEMO® BT immersible pump conveying beet pulp straight from the lagoon with low material wear

Beets, particularly sugar beets and specially-bred energy beets, are becoming more and more popular. The storage of the beets in silos or silage tubes is complicated and expensive. Collecting beet pulp in foil-lined reservoirs represents a comparatively simple and cost-effective alternative to this. More...

Hydroelectric Power Stations Rely on NOTOS® Multi Screw Pumps

Hydraulics and lubrication for turbines weighing many tonnes: Brazilian hydroelectric power stations rely on pump know-how from Germany

Responsible for the environment and climate change, renewable energies are becoming increasingly important. Therefore, where the prerequisites are met, more and more hydroelectric power plants are being connected to the grid. More...

Save Electricity and Substrate Feeding with the NEMO® B.Max® Mixing Pump

Operating small biogas plants efficiently: Special feed and homogenisation technology saves power and substrate

The reason for the slowdown of the large biogas boom in Germany were the reductions in subsidies and above all changes in aid made by the amendment to the German Renewable Energies Act (EEG). More...

NEMO® Progressing Cavity Pumps Process Everything

Robust pumps enable a range of substrates to be conveyed, from liquid manure to food waste

Biogas is in high demand as a source of energy for power and heat generation. Systems that not only process crops specifically grown for power and heat generation, but also use otherwise useless bio waste, are excellent for the environment and are highly economical. More...

NETZSCH product portfolio in the fields of environment and energy

Pompa NEMO® Progressing Cavity

Pompa NEMO® Progressing Cavity dapat digunakan pada berbagai aplikasi dan industri secara luas untuk pengaliran secara kontinyu, bertekanan stabil, lembut, dan low – pulsation pada hampir berbagai jenis substansi. Salah satu keuntungan bagi pemakainya adalah karena pompa ini benar – benar merupakan pompa jenis valveless positive – displacement maka pompa ini juga dapat mengalirkan bahan berserat.

informasi lebih lanjut

Pompa TORNADO® Rotary Lobe

Pompa NETZSCH TORNADO® yang bersifat self-priming, valveless, positive displacement dapat disesuaikan untuk memenuhi tuntutan proses dan aplikasi yang bersangkutan. Pompa – pompa tersebut dapat digunakan pada hampir semua media pada aplikasi untuk penggunaan secara intermiten/berselang, kontinyu, ataupun dosing. Keuntungan TORNADO® adalah kebutuhan tempat yang kecil karena desain yang terpadu, kinerja yang tinggi, dan kehandalan operasi yang tinggi, serta pump head dan bearing housing yang dapat dipisahkan dengan mudah. Pompa TORNADO® mudah untuk diservis dan dirawat; seluruh suku cadang yang bersentuhan dengan media dapat dijangkau tanpa perlu dilakukan pembongkaran saluran pipa ataupun pelepasan bagian motor.

informasi lebih lanjut

NOTOS® Multi Screw Pumps

The NOTOS® family has superior quality standards to meet the highest level requirements from our customers. The pumps are designed to work with low to high lubricant fluids, low to high viscosity, shear sensitive and/or chemically agressive media.

More information

NETZSCH Grinding

Sistem grinding NETZSCH dapat digunakan dimanapun saat pemecahan / pengecilan ukuran padatan sangatlah penting / padatan harus dikecilkan ukurannya untuk menjaga terjadinya sumbatan pada pipa yang dapat merusak peralatan utama.

more information