Convey the Beet Pulp Directly from the Lagoon:

Low Material Wear in spite of High Loads with the NEMO® BT Immersible Pump

Despite the high load, the material wear of the NEMO® BT immersible pump remains low during the conveyance of beets in biogas production.

Beets, particularly sugar beets and specially-bred energy beets, are becoming more and more popular.

Look behind the scenes

The storage of the beets in silos or silage tubes is complicated and expensive. Collecting beet pulp in foil-lined reservoirs represents a comparatively simple and cost-effective alternative to this.

Challenge accepted

In a specific application, around 10 m³ per hour of finely diced beet was to be transported to the fermenter. However, as a semi-solid oxidation layer forms on the pulp in the lagoon, the high-viscosity substrate must be drawn off underneath this layer of scum. Horizontally installed pumps at the edge of the tank or of the pontoon can’t raise the high suction performance. On the other hand, the challenges were the low pH value of the sugar beet pulp and the high, abrasive sand content of up to 10 percent of the substrate volume.

Excellently solved

For this application, a NEMO® BT immersible pump was therefore installed. These are also used elsewhere for emptying tough to high-viscosity media such as crude oil out of tanks and pits. For this application, NETZSCH's developers therefore fitted a stator made of highly-resistant NEMOLAST® elastomer and a wear-resistant rotor. In addition, the pump is operated at an appropriate speed at about 190 rpm which increases its service life. Material wear could therefore be kept low in spite of high stresses.

NEMO® BT immersible pump

  • Medium: Beet pulp
  • Throughput volume: 10 m³/h
  • Rotations speed: 190 rpm
  • Pressure: 24 bar
  • Depth: Max. 10 m
Material wear of the NEMO® progressing cavity pump remains low during the conveyance of beets.

 

You may also be interested in:

NEMO® B.Max Mixing Pump

The NEMO® B.Max is setting new standards with its maximum mixing and conveying capabilities for biosubstrates.

NEMO® SY Industrial Construction in Bearing Block Design with Free Shaft Extension

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

M-Ovas® Grinding System

NETZSCH M-Ovas® grinding systems can be used wherever it is essential that solid matter in fluids be broken down reliably to ensure the prevention of pipe clogging and damage to downstream equipment.