Conveying Materials for Surface Coating:

NEMO® Progressing Cavity Pumps Convey Media in the Paint and Coatings Industry

The printing and ink industry represent one of the most demanding sectors for delivery systems, with areas of application including the reliable supply of abrasive paper fillers and corrosive gluing agents, along with the exact metering of high-viscosity printing inks and varnishes.

Behind the scenes

One of the major problems facing conventional pumps is the lack of fluidity of the inks. It is not uncommon to see viscosities of 10,000 mPas or more, which means that achieving a continuous supply is very challenging and inferior pumping solutions can suffer under the stress and become blocked quickly.

Challenge accepted

A renowned printing house was struggling with repeated breakdowns of the diaphragm pumps used to refill offset ink at roughly 10,000 mPas from the transport truck to the storage tank. Because of this inadequacy, the unloading process was being greatly delayed and the pumps needed maintenance work, often requiring them to be removed completely and dismantled, a labour intensive and time consuming task.

Excellently solved 

To increase performance, economy and reliability, the company decided to use our NEMO® progressing cavity pumps, a single-stage pump model with L-geometry rotor and stator allowing for a higher delivery rate at a lower differential pressure. The slim-line units with frequency inverter and smaller rotor:

  • Prevented excessive clamping thereby improving mechanical efficiency.
  • Allowed space for multiple pump installations.
  • Enabled easy access to the devices in case maintenance work should become necessary.
  • Ran more reliably and efficiently than the previously employed diaphragm pumps, which resulted in the unloading time for the ink being halved.

Positive displacement pumps from NETZSCH are used in various areas of the ink and paper industry for everything from transporting pigment sludge or additives, to processing fluids and binding agents.
Each scenario requires a different configuration for our pumps depending on their intended use, but the broad experience of our company’s pump experts in this diverse market always results in a suitable combination to resolve any problem.

NEMO® progressing cavity pump

  • Medium: Offset ink
  • Viscosity: 10.000 cP

 

You may also be interested in:

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

NEMO® Progressing Cavity Pump in FSIP® design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.

NEMO® C.Pro Dosing Pump

The NEMO® N-Ipos CY C.Pro dosing pump is a fully synthetic pump for the precise dosing of a great variety of chemicals in environmental technology and the chemical industry. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation conveyance and dosing of aggressive or non-aggressive chemicals.