Exact Mixture of Different Material Components

Combination of several barrel emptying units convey materials without interruption

In silicone production, NBE 200 barrel emptying systems ensure the exact mixing of the most varied material components. 

Several container emptying units in combination convey the materials without interruption. 

Look behind the scenes

The higher the requirements are in terms of the characteristics and high performance of modern materials, the more individual components have to be combined and accurately mixed to produce them. This means correct dosing is essential and accuracy requirements of ±1 percent are not uncommon. 

Challenge accepted

Five different components have to be combined in the right mix ratio for silicone production, including a medium filled with carbon black particles which is highly abrasive effect. The materials need to be taken out of 200-litre barrels and accurately dosed with a pumping capacity of 25 l/m via three existing floor scales.    

Excellently solved

Because two of the components have to be supplied in larger quantities than the others, NETZSCH installed three conventional NBE 200 barrel emptying units, along with two so-called twin versions. These each comprise two of the barrel emptying units and can therefore be switched over to the second barrel after emptying the first without any interruption, while the first one is being replaced. There is clear, combined control of all seven units via a central interface. High strength steel and robust elastomers are used on all pumps for the rotor and follow plate, along with the stator and levelling collar. This ensures that even the medium filled with carbon black can be transported without any increased wear on the system components.

The way the progressing cavity pump itself works also contributes to the long service lives of the barrel emptying units. The slim design with a small number of individual parts is less susceptible to faults than other conveyance technologies and in addition the material – particularly on the seals – is not put under such a heavy strain by the uniform rotation as it is by alternating lifting-lowering movements in piston pumps for example. The external components can also be easily removed for any kind of cleaning and maintenance work, which significantly reduces the length of any disruptions to operations. Together with ensuring high conveyance volume and uninterrupted dosing even of larger quantities via the twin system, it was thus possible to reduce the processing time for individual production orders by around 50 percent. A silicone manufacturer has therefore been able to simplify the extraction and dosing of their different basic substances and to roughly halve the production time.

Get an individual offer for your application now!

NBE barrel emptying unit

  • Medium: Silicone
  • Throughput volume: 25 l/min
  • Pressure: 18 bar
  • Viscosity: 50.000 to 250.000 cP
The way the progressing cavity pump itself works also contributes to the long service lives of the barrel emptying units.

 

You may also be interested in:

Barrel Emptying System with NEMO® BH Pump

NEMO® barrel emptying systems for hygienic applications are highly versatile and automatically suck themselves towards the bottom of the barrel.

NEMO® Dispensers and Handdispensers

NEMO® dispensers guarantee the highest level of precision in dosing and reproducibility. For this reason, they are employed in a great variety of applications and industries.

Barrel Emptying System with NEMO® BY Pump

NEMO® barrel emptying pumps suction themselves automatically to the bottom of the barrel or container to achieve almost residue-free emptying in the chemical, pharmaceutical and foods industries. 

NEMO® BT Immersible Pump With Hanging Bracket or Dome Cover Flange

NEMO® Immersible Pumps are used for emptying barrels, tanks, and pits. They are also used where space is limited and the danger of cavitation may be present. In addition, these pumps are suitable for emptying barrels containing materials hazardous to water and the environment.