Gentle and Flexible Delivery of Edible Oil:

TORNADO® T.Sano® Rotary Lobe Pump Meets High Standards of Hygiene

Look behind the scenes

In everyday practice in the foodstuff industry high demands on hygienic processing are required for the primarily sensitive products, simultaneously, there is the high pressure of competition and efficiency.  

Challenge accepted

According to the manufacturer, barrels of 50 to 200 litres, IBC barrels and complete tankers of 30 cubic metres volume had to be filled within a maximum of one hour with different types of edible oils. Due to the different types of containers for transportation, stationary delivery equipment cannot be considered, instead, up to present, a geared pump installed on a small trolley has been used. However, this was not at all satisfactory, because the gears of the pump were overloaded.  

Excellently solved

In order to reduce the high wear and, thus, the resulting frequent maintenance, the system was changed last year to a mobile TORNADO® T.Sano rotary lobe pump. However, for the design of the pump, the particular characteristics of the edible oil must also be taken into consideration. In another plant, the centrifugal pumps used would have shattered the oil into droplets. Pulsation can cause a problem for rotary lobe pumps, too. Thus, in order to reduce this, multiple bladed lobes are usually used for sensitive media. In contrast, NETZSCH relies on the special design of the delivery chamber of the TORNADO® T2 series. Small pockets, machined into the inner wall, make sure that the material can smoothly flow into the delivery chamber. The pulsation of the two-bladed lobe thereby remains at the level of a four-bladed lobe, so that the edible oil can be filled without changing its consistency. So that the pump system, together with all the accessories, can be easily used and moved between the filling positions, a compact construction and low weight were important factors. Due to its innovative drive technology, the T.Sano has a specific advantage: Instead of the usual, but very complex and heavy timing gear, a much lighter belt drive is used for this series. Thus, the flexibility required by the manufacturer is assured in all application situations. In addition, the belt drive simplifies any maintenance tasks and requires no lubrication. Due to the continuous hard-soft contact between drive, belt and shafts, a high level of smooth running is attained, which protects the components in general. The T.Sano fulfils the delivery function to the complete satisfaction of the oil producer.


NETZSCH: TORNADO® T.Sano rotary lobe pump
Medium: edible oil
Throughput volume: 27 m³/h
Rotations speed: between 150 and 440 rpm
Pressure: 4 bar


NETZSCH Barrel Emptying Pumps

NEMO® barrel emptying pumps suction themselves automatically to the bottom of the barrel or container to achieve almost residue-free emptying in the chemical, pharmaceutical and foods industries. 

NEMO® Pump BY

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

NEMO® SY Industrial Construction in Bearing Block Design with Free Shaft Extension

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

NEMO® SA Aseptic Pump

The NEMO® SA aseptic pump is employed for aseptic and hygienic applications in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries in order to provide continuous, pressure-stable, gentle and low-pulsation conveyance and dosing in proportion to speed.

NEMO® Mini BH Hygienic Pump

The NEMO® Mini BH hygienic pump is employed above all in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries for hygienic applications. It is ideal in these settings due in part to its continuous, pressure-stable, smooth and low-pulsation conveyance and in part to its capability of dosing in proportion to speed.