The NEMO® progressing cavity pump with open hopper and dry-running protection in the food industry conveys hot and abrasive spent grains in a brewery.

In 1996 two friends with a passion for brewing premium beer opened the doors to the Brewing Company, a bar, restaurant and brewery in Downingtown, Pennsylvania. From a converted factory building where they brewed 1,725 barrels of beer in their first year.  

Look behind the scenes

More recently the company has opened a second, state-of-the-art brewery in Parkesburg, Pennsylvania. The 19,700 square meter building features a brew house with a production of about 10 brews a day for an annual output of approximately 225,000 barrels. For a brewery with such high demand for its premium beers, the company needs pumping equipment of the highest reliability, maintainability and service life.  

Challenge accepted

Spent grain in the beer brewing process can vary in character, but it is typically hot up to 65°C and can vary widely in moisture levels. It is always abrasive, and significant pressure may need to be generated if the spent grain is to be pumped long distances.    

Excellently solved

NEMO® progressing cavity pumps are designed with elastomer stators which can expand with the heat from the spent grain. To counteract this expansion, the rotor is engineered with a reduced diameter to maximize performance and minimize the torque as it rotates within the stator. In addition a dry run protection was provided with this pump. “To this point, we have done no maintenance on the NETZSCH pump in the Parkesburg brew house. We just let it run. The same NETZSCH pump that conveys spent grain in our Downingtown facility ran for four or five years before the stator needed replacing”, the Vice President accords, even though the spent grain is pumped approximately 250 feet to the spent grain silos outside the brewery.

NEMO® progressing cavity pumps with an inlet hopper

  • Medium: Spent grain
  • Throughput: Volume 16 m³/h
  • Rotations speed: 100 up to 150 rpm
  • Pressure: 5 up tp 18 bar Viscosity 10.000 cPs
  • Temperature: 65 °C
A patented auger feed at the base of the inlet hopper over-feeds the wet but non-flowing spent grain into the NEMO® progressing cavity pump to ensure conveyance.

 

You may also be interested in:

NEMO® C.Pro Dosing Pump Made of Synthetic Materials

The NEMO® C.Pro dosing pump is a fully synthetic pump for the precise dosing of a great variety of chemicals in environmental technology and the chemical industry. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation conveyance and dosing of aggressive or non-aggressive chemicals.

NEMO® BO/BS Pump with Hopper in Block Construction

The NEMO® BO/BS progressing cavity pump with square/rectangular hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NETZSCH Barrel Emptying Pumps

NEMO® barrel emptying pumps suction themselves automatically to the bottom of the barrel or container to achieve almost residue-free emptying in the chemical, pharmaceutical and foods industries. 

NEMO® Mini BH Hygienic Pump

The NEMO® Mini BH hygienic pump is employed above all in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries for hygienic applications. It is ideal in these settings due in part to its continuous, pressure-stable, smooth and low-pulsation conveyance and in part to its capability of dosing in proportion to speed.