NEMO® Progressing Cavity Pumps from NETZSCH:

Have a Wide Range of Applications and are Used in Many Areas

NEMO® progressing cavity pumps have a very broad application range and are used in all branches of industry for the continuous, pressure-stable, gentle and low-pulsation conveyance of almost any substance.

One advantage for the operator is that such valveless positive-displacement pumps are also capable of transporting stringy material safely. Whether for sludge, chemical substances, adhesives, petroleum or yogurt, one of the eleven pump types by NETZSCH in four rotor/stator geometries and a selection of engineered joints make sure to suit your application. 

Function of the NETZSCH NEMO® Progressing Cavity Pump

To further increase the service life of NEMO® progressing cavity pumps in wear-intensive applications, NETZSCH Pumpen & Systeme GmbH has developed a special stator adjustment unit, called xLC® unit, which is based on the easy-to-replace and easy-to-maintain iFD® stator 2.0. If the sealing line between the conveying elements rotor and stator fails due to wear, compressing the elastomer can easily and quickly restore the pre-tensioning, and with it the pump performance. Moreover, an integrated display provides information about the readjustment status of the stator and when a stator change is impend at all times. Thus the tool ensures more operational and planning safety. To minimize the wear, the xLC® system canbe combined, for example, with joints and seals as well as special wear coatings for rotors. 

Function of the NETZSCH xLC® Stator Adjustment System

Product Range of the NEMO® Progressing Cavity Pump

NEMO® Progressing Cavity Pump in FSIP® design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.

NEMO® BH Hygienic Pump in Block Design

The NEMO® BH is employed in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries for hygienic applications and optimal cleaning. It is ideal in these settings due in part to its continuous, pressure-stable, gentle and low-pulsation conveyance and in part to its capability of dosing in proportion to speed.

NEMO® BO/BS Pump with Hopper in Block Construction

The NEMO® BO/BS progressing cavity pump with square/rectangular hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® BF Progressing Cavity Pump with Hopper and Feeding Screw

The NEMO® BF is used in all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance with dosing in proportion to rotation speed. It is employed primarily for highly viscous, compacted and crumbly substances that do not have a tendency to bridge.

NEMO® BY Block Pump in Industrial Design

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

NEMO® Mini BH Hygienic Pump

The NEMO® Mini BH hygienic pump is employed above all in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries for hygienic applications. It is ideal in these settings due in part to its continuous, pressure-stable, smooth and low-pulsation conveyance and in part to its capability of dosing in proportion to speed.

NEMO BO/SO Hopper Pump with Integrated Cutting Device

The NEMO® BO/SO progressing cavity pump with hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to  provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® BT Immersible Pump with Hanging Bracket or Dome Cover Flange

NEMO® Immersible Pumps are used for emptying barrels, tanks, and pits. They are also used where space is limited and the danger of cavitation may be present. In addition, these pumps are suitable for emptying barrels containing materials hazardous to water and the environment.

NEMO® SY Industrial Construction in Bearing Block Design

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

NEMO® SH Plus Hygienic Pump in Bearing Block Design

The NEMO® SH Plus hygienic pump is employed for hygienic applications in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries in order to provide continuous, pressure-stable, gentle and low-pulsation conveyance with optimal cleaning and dosing in proportion to speed.

NEMO® BP Hopper Pump with Feeding Screw and Bridge Breaking Paddle

For highly viscous, compacted and crumbly substances that have a tendency to bridge, the NEMO® BP is the optimal solution. The NEMO® BP can be used in nearly all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance with dosing in proportion to rotation speed.

NEMO® C.Pro Dosing Pump Made of Synthetic Materials

The NEMO® C.Pro dosing pump is a fully synthetic pump for the precise dosing of a great variety of chemicals in environmental technology and the chemical industry. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation conveyance and dosing of aggressive or non-aggressive chemicals.

NEMO® SA Aseptic Pump in Bearing Block Design

The NEMO® SA aseptic pump is employed for aseptic and hygienic applications in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries in order to provide continuous, pressure-stable, gentle and low-pulsation conveyance and dosing in proportion to speed.

NEMO® B.Max Mixing Pump in Block Design

The NEMO® B.Max is setting new standards with its maximum mixing and conveying capabilities for biosubstrates.