Crude Oil Unloading at an Industrial Rail Terminal

NOTOS® multi screw pumps from netzsch ensure a high flow with low noise

In order to minimize the noise level and increase efficiency, an operator of an industrial rail terminal has decided to upgrade the system with several NOTOS® multi screw pumps from NETZSCH.

High flow with low noise – Multi screw pumps replace gear pumps at an industrial rail terminal.

Gear pumps cause high noise pollution in an industrial rail terminal

A major industrial rail terminal operator in the United States initially wanted to improve the noise level and operation of a rail car unloading pump for crude oil at their facility. The tank terminal design included a rail car unloading rack employing three gear pumps. Because these pumps were sensitive to changing weather conditions, they would vibrate. One of these pumps was extremely noisy with more than 100 decibels (equivalent to the noise of a jackhammer) so that the operator decided to change it.

Operator contacts NETZSCH for alternative

To reduce noise and increase the efficiency of the system the operator contacted NETZSCH to provide a better pump solution. A visit was made to the rail car unloading facility to get an overview of the system requirements. During the visit, it was discovered that the terminal not only wanted to replace that specific noisy gear pump. As the terminal was in the process of designing two more unloading racks with three pumps per rack they needed six new pumps.

NOTOS® multi screw pump solves the problem with a quiet and efficient operation

Together with the customer the operating parameters were established. These included a greater viscosity range of the crude oil and a desired higher flow that this terminal wanted to incorporate as part of their growth. The API grade of the incoming crude oil at this terminal could be as low as 10 API and as high as 52 API which is a significant variation in viscosity. This significant variation in product viscosity would also cause changes in the system pressures during unloading. Temperature changes could also change the viscosity of the product. Along with this, the pump had to meet API 676 requirements. Furthermore, stripping railcars can cause a pump by itself to run dry (without fluid) for short periods of time.

Based on these demanding characteristics, NETZSCH designed a pump system individually tailored to the customer. A NOTOS® 4NS multi screw pump using double mechanical cartridge seals with an external flushing system with the following highlights:

  • low NPSHr, therefore the pump can operate without cavitation
  • quiet running characteristics
  • high efficiency regardless of viscosity of the crude oil being pumped; thereby lowering operating cost
  • By employing a double mechanical cartridge seal the pump can run dry without damage to the pump seals as they are lubricated by an external seal flushing system

All of these highlights combined with the excellent service and expertise of the local NETZSCH Team convinced the customer to invest in the new pumping system for their rail car unloading project.

Get an individual offer for your application now!

NOTOS® multi screw pump 4NS

  • Medium: Crude Oil
  • Flow rate: 216 m3/h
  • Pressure: 5,2 bar
  • Temperature: up to 77 °C

You may also be interested in:

NEMO® SY Industrial Construction in Bearing Block Design

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

NEMO® BY Block Pump in Industrial Design

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.

TORNADO® T.Envi® Rotary Lobe Pump

The TORNADO® T.Envi® rotary lobe pumps in FSIP® design are optimally adapted to your requirements in environmental and biogas technology and impress with easy maintenance.

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.