Convey Kaolin Slurry Quickly and Reliably

TORNADO® rotary lobe pumps also pump in the paper and pulp processing industry

Flexible rotary lobe pumps convey kaolin slurry quickly and reliably despite reduced space

 "White gold" – this description of porcelain was also used in the past for paper, for a good reason. Both are based on kaolin, a special clay that gives the materials their radiant white. Kaolin is not only used as a coating in paper production, but as a filling as well.    

 

Background

For cost reasons, a paper company decided to switch production processes to delivery by rail. In contrast to the lorries that had been used, rail would allow larger volumes to be transported, so purchasing would be more cost-effective. However, the standing times of the private rail company had to be kept as short as possible. At the same time, there were only a few square metres available in the pump room. The progressing cavity pumps used in the past could not have been installed in the quantity required.

Challenge

The special properties of the conveyor medium were also an important consideration. The basic raw material for white porcelain clay is feldspar. When it decomposes, kaolinite forms, which then combines with smaller proportions of undecomposed feldspar and quartz to make the actual kaolin. The individual particles have a layered structure and are generally just a few µm in size. Kaolinite itself is quite soft at 2.5 on the Mohs scale. However, the additional proportions of feldspar and quartz can make the clay - which is mainly softened to a slurry for processing - quite abrasive. The pump therefore had to be designed to withstand more challenging media during everyday use as well, and to deliver consistent performance. Centrifugal pumps would not have been suitable for the task because of the anticipated issues with low pressure and counter pressure.

 

Solution

The decision ultimately was to use the TORNADO® rotary lobe pump system, as it delivers exceptional flexibility. A total of five pumps were installed for the paper manufacturer. They convey around 70 m³ of the kaolin slurry at a viscosity of between 100 and 500 mPas. The pumps were made from a highly corrosion-resistant CrNiMo steel to maximize running times and minimize maintenance workload. Axially and radially abrasion-resistant wear protection plates are also attached and can be easily replaced if necessary. The outer body of the multiple-bladed lobes is made of hard-wearing sodium butadiene rubber with low shore hardness and especially suited to abrasive products. If cleaning and repair is required nonetheless, the front of the pump chamber can be removed in just a few steps. The entire conveyor area is therefore easily accessible so that the individual components can be serviced or replaced without having to remove the housing. A further significant contributor to the robustness of the TORNADO® is the Gearbox Security System (GSS) which physically separates the pump and gear chambers. The sensitive gear box is thereby completely protected against the ingress of fine slurry. The springs of the mechanical seal on the shaft have also been encapsulated to prevent damage to the components. The pumps, which traditionally convey horizontally, have been rotated 90° to the right to fit into the limited space. The infeed and outfeed ports are now at 12 and 6 o'clock. Each TORNADO® now takes up just 1 m² of the small pump room. The total unloading procedure lasts just a few hours despite the large volumes supplied – and the rental periods for the rail transport are shorter as a result. 

 

TORNADO® rotary lobe pump

  • Medium: Kaolin slurry 
  • Throughput volume: 70 to 75 m³/h
  • Pressure: 4 bar
  • Viscosity: 100 to 500 cP

 

You may also be interested in:

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다

TORNADO® 로터리 로브 펌프 T2

TORNADO® 로타리 로브펌프는 용적식 펌프의 종류입니다. 펌핑 동작은 펌프 챔버 내에서 반대방향으로 회전하는 2개의 로터에 의해 발생합니다. 유체는 흡입구를 통해 펌프 챔버에 들어오며, 로터에 의해 챔버 주변를 따라 이동 , 토출구를 통해 이송됩니다.

TORNADO® T.Sano® Rotary Lobe Pump in Smooth Surface

The innovative design of the TORNADO® T.Sano® rotary lobe pump in Smooth Surface has a completely smooth housing in comparison to the standard T.Sano®, which attracts barely any dirt or dust. The whole T.Sano® series are EHEDG-certified.