Conveying of Fatty Acids from Tank Trucks

TORNADO® T.Proc® rotary lobe pumps meet even the most stringent requirements

Special rotary lobe pumps meet even the strictest legal requirements at the conveying of fatty acids

Every commercial and industrial company in Europe is subject to a multitude of regulations for the protection of staff, users and the environment. This not only affects the manufacturing machines themselves, but also the pump systems being used.                   

 

Look behind the scenes

It is above all the cosmetics industry and the paint and varnish industry which use fatty acids in their production processes. Depending on the chemical composition, concentration and volatility, the acids can burn the skin or even the respiratory tract, if there is no protection against contact. The medium therefore comes under the area of the Technical Instructions on Air Quality (TA Luft), which contain emissions and emissions limit values, not only for gases, but also for all types of hazardous substances and environmental pollutants. They stipulate that fatty acids must not come into contact with the atmosphere.  

 

Challenge accepted

The existing geared pump, which the manufacturer had been using up to this point to feed its tankers, was no longer able to meet this requirement and therefore had to be replaced. In addition, the sticky and temperature-sensitive medium has to be conveyed at 70°C to keep it free-flowing. At the same time, the installation area is Ex zone 1 due to possible gas accumulations, which means the pump has to be ATEX-compliant.  

 

Excellently solved

In order to fulfil both regulations, TA Luft and ATEX, at the start of 2014 the operating company had a rotary lobe pump of the T.Proc® type installed which was specifically developed for this kind of difficult media. An all-metal design was chosen due to the aggressive substance and the high conveying temperatures. The high-strength steel used for this is extremely resilient, which ensures a long service life for the pump. In addition, this material enables manufacture with very small clearances between the rotary lobes and the housing, which gives a high level of efficiency. Meanwhile, the pump has been reliably doing its job since begin of 2014 and filling the manufacturer's tankers at a volume of 20 m³/h and a pressure of 2.5 bar. In doing so, all the legal requirements have been strictly adhered to, including the TA Luft air quality specifications.

TORNADO® T.Proc® rotary lobe pump

  • Medium: Fatty acids
  • Throughput volume: 20 m³/h
  • Pressure: 2.5 bar
TORNADO T.Proc Rotary Lobe PumpAn all-metal design of the T.Proc® was fitted, due to the aggressive medium and the high conveying temperatures.

 

You may also be interested in:

TORNADO® 로터리 로브 펌프 T2

TORNADO® 로타리 로브펌프는 용적식 펌프의 종류입니다. 펌핑 동작은 펌프 챔버 내에서 반대방향으로 회전하는 2개의 로터에 의해 발생합니다. 유체는 흡입구를 통해 펌프 챔버에 들어오며, 로터에 의해 챔버 주변를 따라 이동 , 토출구를 통해 이송됩니다.

Barrel Emptying System with NEMO® BY Pump

NEMO® barrel emptying pumps suction themselves automatically to the bottom of the barrel or container to achieve almost residue-free emptying in the chemical, pharmaceutical and foods industries. 

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다