Conveying Sewage Sludge with High Strength

NEMO® BP progressing cavity pump with abp-module® prevents system downtime

The NEMO® BF progressing cavity pump with aBP Module® prevents system downtime in a sewage treatment plant despite the high strength of the sewage sludge.

There are two aspects of wastewater treatment plants at Celle (Germany) which have a direct use: in addition to cleaning waste water, the sewage sludge which arises with the nutrients it contains can be used later as manure in agriculture.  

Look behind the scenes

The sewage sludge is transported via a pressure pipe around 25 metres in length with several right-angled turns – ten metres of it being geodesic – to a silo and from there it is later spread over agricultural areas. So that the mix can be stored, it is first dewatered in an angle press and flocculating agents are added.

Challenge accepted

Because of the high cohesiveness which caused repeated entanglements and bridge building. "The operational downtime amounted to three to four hours a week in all", says the Area Sales Manager from NETZSCH. The wastewater treatment plant need a reliable system without shutdowns.  

Excellently solved

The pump specialists from Waldkraiburg developed the aBP-Module®. It comprises a top hopper with two spoked wheels attached to its internal sides. The wheels sit deep inside the hopper and are very close to the walls. When they turn, the effect on the medium being poured in is as if the whole hopper sides were moving. The pumping system with the integrated bridge breaker has also proved itself in continuous operation. Operational reliability has increased considerably, while it has been possible to almost completely do away with inspections for the conveyor, which had been standard up to this point. "The plant and the aBP module have proved to be very robust," reports the expert from NETZSCH. "Since then there have been no more operational shutdowns."

Get an individual offer for your application now!

NEMO® progressing cavity pumps BF with aBP-Module®

  • Medium: Sewage sludge
  • Throughput volume: 2 up to 5 m³/h
  • Rotations speed: Under 30 rpm
  • Pressure: 12 up to 15 bar
  • Dry matter contents: 25-35%
  • Viscosity: Between 10 and 22 Pas
In order to convey a high viscosity sludge with the required pressure in a wastewater treatment plant, NEMO® BF progressing cavity pump is applied.

 

You may also be interested in:

NEMO® BF Hopper-Shaped Progressing Cavity Pump With aBP-Module®

The NEMO® BF hopper-shaped progressing cavity pump with aBP-Module® to prevent bridging is used in all branches of industry for continuous, pressure-stable, gentle and low-pulsation conveyance as well as dosing in proportion to speed, especially for highly viscous, compacted and crumbly media.

The NETZSCH TORNADO® Mobile

A TORNADO® rotary lobe pump fastened onto a mobile base – this is the NETZSCH TORNADO® Mobile. The concept of mounting the equipment onto a car or truck trailer makes it possible to pump large quantities of fluids with solid content, wastewater and slurries at the most unusual of sites.

M-Ovas® Universal Cutting Plate Macerator

With the universally applicable M-Ovas® cutting place macerator, you can prevent possible damage to your pump caused by impurities.

NEMO® BF Progressing Cavity Pump With Hopper and Feeding Screw

The NEMO® BF is used in all branches of industry to provide continuous, pressure-stable, gentle and low-pulsation conveyance with dosing in proportion to rotation speed. It is employed primarily for highly viscous, compacted and crumbly substances that do not have a tendency to bridge.