Rotary lobe pump meets the challenge of highly abrasive bonding primer and achieves three times longer service life

One of the products which the building materials manufacturer Knauf makes in Iphofen is a concrete primer.  

 

Look behind the scenes

What is intended to ensure that plaster evenly bonds onto smooth walls in construction does however create problems when filling: the plaster primer contains dispersion and has a mineral solid content of around 60 percent, which has an effect like emery paper in the rotary lobe pump feeding the filling station.  

 

Challenge accepted

The high annual production capacity on the mixing system meant a considerable maintenance effort. "At busy times we were repairing the pump every 3 to 4 weeks," reports the Maintenance Manager of the company. Reason enough to look round for an alternative and this was found with NETZSCH.  

 

Excellently solved

A TORNADO® T.Proc 08/45 BD-E was installed in April 2012. So as to be equipped for challenges of this kind, the whole materials concept of conventional rotary lobe pumps was reversed when the TORNADO® was redesigned: two lobes made of hardened steel are used here, which rotate in a geometrically adapted elastomer insert, instead of the standard elastomer lobes. This means energy is saved, wear is reduced and the service life of the pump is increased overall. At the time of the first inspection, the pump had already delivered double the volume of the conventional rotary lobe pump used up to this point. Only 60% of the maximum speed had been reached at this time. "So we still have a lot more potential," said an NETZSCH Expert. "Based on the operating time so far, the T2 can certainly achieve three times the service life." This supposition has now been confirmed after six months' operation: with 3-4 times the conveyance there has been more than three times the service life.

TORNADO® T.Proc®

  • Medium: Plaster primer
  • Throughput volume: Between 1.500 and 5.000 kg/h

 

You may also be interested in:

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다

NEMO® C.Pro

NEMO® N-Ipos CY C.Pro 도징 펌프는 환경 및 화학산업에서 사용되는 다양한 화학물의 정량이송을 위한 온전한 합성소재 펌프입니다. 합성소재 구조는 부식성이 심하거나 심하지 않은 화학물을 부드러운 저맥동으로 이송하는 데 적합합니다.

more information

TORNADO® 로터리 로브 펌프 T2

TORNADO® 로타리 로브펌프는 용적식 펌프의 종류입니다. 펌핑 동작은 펌프 챔버 내에서 반대방향으로 회전하는 2개의 로터에 의해 발생합니다. 유체는 흡입구를 통해 펌프 챔버에 들어오며, 로터에 의해 챔버 주변를 따라 이동 , 토출구를 통해 이송됩니다.