Brewers from Pennsylvania Counts on Bavarian Pumps:

NEMO® Progressing Cavity Pumps with Open Hopper Convey Abrasive Spent Grains

Pennsylvania Brewing Company counts on Bavarian pump technology

In 1996 two friends with a passion for brewing premium beer opened the doors to the Brewing Company, a bar, restaurant and brewery in Downingtown, Pennsylvania. From a converted factory building where they brewed 1,725 barrels of beer in their first year.  

 

Look behind the scenes

More recently the company has opened a second, state-of-the-art brewery in Parkesburg, Pennsylvania. The 19,700 square meter building features a brew house with a production of about 10 brews a day for an annual output of approximately 225,000 barrels. For a brewery with such high demand for its premium beers, the company needs pumping equipment of the highest reliability, maintainability and service life.  

 

Challenge accepted

Spent grain in the beer brewing process can vary in character, but it is typically hot up to 65°C and can vary widely in moisture levels. It is always abrasive, and significant pressure may need to be generated if the spent grain is to be pumped long distances.    

 

Excellently solved

NEMO® progressing cavity pumps are designed with elastomer stators which can expand with the heat from the spent grain. To counteract this expansion, the rotor is engineered with a reduced diameter to maximize performance and minimize the torque as it rotates within the stator. In addition a dry run protection was provided with this pump. “To this point, we have done no maintenance on the NETZSCH pump in the Parkesburg brew house. We just let it run. The same NETZSCH pump that conveys spent grain in our Downingtown facility ran for four or five years before the stator needed replacing”, the Vice President accords, even though the spent grain is pumped approximately 250 feet to the spent grain silos outside the brewery.

기술사양

기술사양

NETZSCHNEMO® progressing cavity pumps with an inlet hopper
MediumSpent grain
Throughput volume  16 m³/h
Rotations speed  100 up to 150 rpm
Pressure 5 up tp 18 bar
Viscosity10.000 cPs
Temperature 65°C

제품 소개

제품 소개

NEMO® 식음료 펌프

NEMO® 식음료 펌프는 와인 재배, 생산, 양조장 및 각종 음료 생산 사업에 사용됩니다. 편리한 이동식 장치는 생산 환경에 필요한 유연성을 제공합니다.

NEMO® BO/BS 호퍼 모노펌프 (직경형 디자인 & 플랜지타입 모터)

NEMO® BO/BS 모노펌프는 정사각형/직사각형의 호퍼와 강제 이송 스크류 타입의 커플링 로드 강제이송 챔버를 구조를 하고 있으며, 대부분의 모든 산업분야에 적용되어 연속적이고 안정적인 압력 부드러운 저맥동의 이송을 제공합니다.

NETZSCH Barrel Emptying Pumps

We’ll get the very last of it out for you!

NEMO® C.Pro

NEMO® N-Ipos CY C.Pro 도징 펌프는 환경 및 화학산업에서 사용되는 다양한 화학물의 정량이송을 위한 온전한 합성소재 펌프입니다. 합성소재 구조는 부식성이 심하거나 심하지 않은 화학물을 부드러운 저맥동으로 이송하는 데 적합합니다.

more information


문헌

문헌