Processing Various Substrates into Biogas:

NEMO® Progressing Cavity Pumps Process Everything from Liquid Manure to Waste

The space-saving NEMO® progressing cavity pumps convey a wide variety of substrates during the production of biogas without major maintenance work or breakdowns.

In addition, the pumps are distinguished by their long service life.

Look behind the scenes

This example follows Agrivalor Énergie in Alsace, which feeds its cogeneration plant with biogas from leftover food production and food that has passed its sell-by-date. Mixtures from maize silage, liquid manure, and grape marc, but also food waste from restaurants, schools and supermarkets are conveyed into a mixing tank from where they travel on to the fermenter, where the biogas is formed.  

Challenge accepted

However, the varying mixtures of materials put a major strain on the plant’s conveying systems. Some of the materials, such as the liquid manure, are corrosive and some are fibrous and likely to cause obstructions, such as grain waste. Materials of animal origin also have to be exposed to intense heat to prevent disease, so some media are still at 70 or 80°C when they are conveyed.  

Excellently solved

Agrivalor Énergie ordered ten NETZSCH-made NEMO® progressing cavity pumps to achieve maximum possible reliability without significant maintenance or downtimes, despite the tough conditions. Two of the larger pumps with capacities of around 40 m³/h are used to transport the mixture from the collecting tank (with around six to seven percent dry matter content) into the fermenter. Other NEMO® pumps with a capacity of 20 m³/h are used to convey the recirculated substance and introduce the sanitised hot liquid manure into the mixer. All the units are extremely compact and have a block design with flange-mounted motor, saving a lot of space on the premises of the privately owned biogas plant. The efficient pump design only requires minimal power, which – along with the long service life and long maintenance intervals – leads to low overall operating costs.

NEMO® progressing cavity pump

  • Medium: maize silage, liquid manure, grape marc, food waste, fats and dairy products
  • Temperature: 70 up to 80 °C
  • Conveying capacity: 20 up to 40 m³/h

You may also be interested in:

NEMO® B.Max 믹싱 모노펌프

NEMO® B.Max 바이오 물질의 최적의 혼합 및 이송을 위한 새로운 기준을 제시하고 있습니다.

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

TORNADO® 로터리 로브 펌프 T2

TORNADO® 로타리 로브펌프는 용적식 펌프의 종류입니다. 펌핑 동작은 펌프 챔버 내에서 반대방향으로 회전하는 2개의 로터에 의해 발생합니다. 유체는 흡입구를 통해 펌프 챔버에 들어오며, 로터에 의해 챔버 주변를 따라 이동 , 토출구를 통해 이송됩니다.

M-Ovas® 그라인딩 시스템

NETZSCH M-Ovas® 그라인딩 시스템은 배관의 막힘을 방지하고 후속 장치의 손상을 방지하기 위해 유체에 포함된 고형물의 분쇄가 필수적일 사용됩니다.