Gentle and Flexible Delivery of Edible Oil:

TORNADO® T.Sano® Rotary Lobe Pump Meets High Standards of Hygiene

Special hygienic rotary lobe pump delivers edible oil flexibly and with care

Look behind the scenes

In everyday practice in the foodstuff industry high demands on hygienic processing are required for the primarily sensitive products, simultaneously, there is the high pressure of competition and efficiency.  

 

Challenge accepted

According to the manufacturer, barrels of 50 to 200 litres, IBC barrels and complete tankers of 30 cubic metres volume had to be filled within a maximum of one hour with different types of edible oils. Due to the different types of containers for transportation, stationary delivery equipment cannot be considered, instead, up to present, a geared pump installed on a small trolley has been used. However, this was not at all satisfactory, because the gears of the pump were overloaded.  

 

Excellently solved

In order to reduce the high wear and, thus, the resulting frequent maintenance, the system was changed last year to a mobile TORNADO® T.Sano rotary lobe pump. However, for the design of the pump, the particular characteristics of the edible oil must also be taken into consideration. In another plant, the centrifugal pumps used would have shattered the oil into droplets. Pulsation can cause a problem for rotary lobe pumps, too. Thus, in order to reduce this, multiple bladed lobes are usually used for sensitive media. In contrast, NETZSCH relies on the special design of the delivery chamber of the TORNADO® T2 series. Small pockets, machined into the inner wall, make sure that the material can smoothly flow into the delivery chamber. The pulsation of the two-bladed lobe thereby remains at the level of a four-bladed lobe, so that the edible oil can be filled without changing its consistency. So that the pump system, together with all the accessories, can be easily used and moved between the filling positions, a compact construction and low weight were important factors. Due to its innovative drive technology, the T.Sano has a specific advantage: Instead of the usual, but very complex and heavy timing gear, a much lighter belt drive is used for this series. Thus, the flexibility required by the manufacturer is assured in all application situations. In addition, the belt drive simplifies any maintenance tasks and requires no lubrication. Due to the continuous hard-soft contact between drive, belt and shafts, a high level of smooth running is attained, which protects the components in general. The T.Sano fulfils the delivery function to the complete satisfaction of the oil producer.


NETZSCH: TORNADO® T.Sano rotary lobe pump
Medium: edible oil
Throughput volume: 27 m³/h
Rotations speed: between 150 and 440 rpm
Pressure: 4 bar


NETZSCH Barrel Emptying Pumps

NEMO® barrel emptying pumps suction themselves automatically to the bottom of the barrel or container to achieve almost residue-free emptying in the chemical, pharmaceutical and foods industries. 

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다

TORNADO® 로터리 로브 펌프 T2

TORNADO® 로타리 로브펌프는 용적식 펌프의 종류입니다. 펌핑 동작은 펌프 챔버 내에서 반대방향으로 회전하는 2개의 로터에 의해 발생합니다. 유체는 흡입구를 통해 펌프 챔버에 들어오며, 로터에 의해 챔버 주변를 따라 이동 , 토출구를 통해 이송됩니다.

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NEMO® SA 무균 모노펌프

NEMO® SA 무균펌프는 식품, 제약, 화장품 화학/바이오화학 산업의 무균 위생 분야에 적용되어 연속적이고 안정적인 압력 부드러운 저맥동의 운전과 운전속도에 비례한 정량이송을 제공합니다.

NEMO® 미니 BH 위생 모노펌프

NEMO® 미니BH 위생형 펌프는 높은 위생성이 요구되는 식품, 제약, 화장품과 화학/바이오화학 산업분야에 적용됩니다.  운전속도에 비례한 정량이송 능력과 연속적이고 안정적인 압력 부드러운 맥동의 이송 덕분에 모델은 이러한 적용에 이상적입니다.