Oil & Gas - Upstream

NETZSCH Upstream conveys extremely difficult media to oil and gas fields

Despite all efforts to promote renewable energies, global demand for crude oil and natural gas has continued unabated. Methane from coal seams and highly viscous oil at more than 10,000 mPas are already of commercial interest, but are just as complicated to extract. In the Qinshui Basin in China the extraction is as difficult as the extraction of oil sand mixtures from the Sudanese desert where temperatures up to 50°C can be reached.

 

Look behind the scenes

The traditional image of oil production using pumpjacks with their distinctive 'donkey' heads is still to be seen on many oil fields around the world. The volumetric efficiency of pumpjacks is only around 30 percent and 35 percent for electrical centrifugal submersible pumps. Therefore pumpjacks are increasingly being replaced by a less spectacular, but more efficient system - progressing cavity oil pumps.

 

Challenge accepted

Highly viscous oils must be conveyed, without pulsation or shear forces, thereby avoiding emulsion effects in oil/water, which would significantly hinder subsequent separation of the oil/water mixtures at the surface.

 

Excellently solved

The volumetric efficiency of a downhole progressing cavity pump is between 75 and 90 percent. The primary success of this technology is its ability to convey highly viscous oils at above 50,000 mPas while maintaining stable pressure. What is more, it can do so with almost no pulsation or shear forces. As the body of the progressing cavity pump is comparatively slim, it is perfectly suited to the interior of the bore hole. NETZSCH has developed various drive heads for different performance and speed requirements to generate the torque above ground. The standard NTZ model has low life cycle costs thanks to its small number of wearing parts and is suitable for oil mixtures with up to 40 percent gas or sand content at up to 160 °C. It can achieve conveyance rates of between 0.5 and 300 m³/d at maximum 300 bar. This type of pump is used, for example, to extract methane in coal seams in the Qinshui Basin in China. The water is removed using the progressing cavity pump until the gas is released and can be collected. An additional flow controller was integrated into the control system to avoid running dry.The metal and elastomer materials are selected to match the anticipated conditions for all types of pump to keep wear from the medium to a minimum while simultaneously creating optimal conditions for conveying. Temperature and density are taken into account, as well as the relative content of water, natural gas and hydrogen sulphide. This approach not only increases the performance of the systems, but also ensures a long service life and long maintenance intervals.

기술사양

기술사양

당신의 모바일기기는 너무 작아서 이 테이블을 볼 수 없습니다.
NETZSCHNTZ - progressing cavity pump
MediumOil-mixture
Throughput volume0.5 up to 475 m³/d
Temperature160°C
PressureUp to 300 bar
Viscositymore than 50.000 cP

More about our Upstream Solutions


제품 소개

제품 소개

TORNADO® 로터리 로브 펌프 T2

TORNADO® 로타리 로브펌프는 용적식 펌프의 종류입니다. 펌핑 동작은 펌프 챔버 내에서 반대방향으로 회전하는 2개의 로터에 의해 발생합니다. 유체는 흡입구를 통해 펌프 챔버에 들어오며, 로터에 의해 챔버 주변를 따라 이동 , 토출구를 통해 이송됩니다.

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NETZSCH TORNADO® 모바일

NETZSCH TORNADO® Mobile - 이동식 베이스에 장착된 TORNADO® 로타리 로브 펌프입니다. 장비를 차나 트럭 트레일러 위에 올려놓을 있는 개념으로 고형물, 폐수, 그리고 슬러리 현장에서 취급하기 어려운 다량의 유체를 이송할 있습니다.

NEMO® C.Pro®

NEMO® N-Ipos CY C.Pro® 도징 펌프는 환경 화학산업에서 사용되는 다양한 화학물의 정량이송을 위한 온전한 합성소재 펌프입니다. 합성소재 구조는 부식성이 심하거나 심하지 않은 화학물을 부드러운 저맥동으로 이송하는 적합합니다.

 more information

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다


문헌

문헌