High Mixing Capacity in Biogas Plants:

NEMO® B.Max Progressing Cavity Pump Convinces through its Robustness Worldwide

In biogas production under the most difficult conditions, the NEMO® B.Max progressing cavity pump convinces through both its high mixing capacity and its robustness.

A conveying screw ensures reliable feeding of the sometimes very viscous biomass. 

Look behind the scenes

The boom of environmentally friendly power and heat generation from renewable biomass continues. Especially countries such as the UK, France, Japan or the US discovered the advantages of renewable energies, primarily the use of biogas. The required know-how and the systems are exported from the technology leaders in Germany, like the conveyor technology specialist NETZSCH. The company manufactures progressing cavity pumps which are especially designed for the difficult substrate mixtures in the biomass sector. These pumps can convey and mix even media with a high content of dry matter. In addition to energy plants, these also allow waste from agriculture and food production to be efficiently converted into energy.  

Challenge accepted

The greatest challenge in biogas production is the composition of the used substrate. Drier ingredients such as chicken manure restrict the flow, plant fibres from grain waste, corn or grass promote clogging while corrosive manure corrodes the materials. Another issue is that other countries often use biowaste for gas production instead of the renewable raw materials used in Germany. If the biowaste contains meat or slaughterhouse waste, it has to undergo hygiene treatment for epidemic protection which can result in high media temperatures of up to 80 °C.  

Excellently solved

To still provide a continuous supply to the fermenter to ensure an uninterrupted fermentation process under these difficult conditions, NETZSCH has adapted its proven progressing cavity pump technology, the NEMO® B.Max pump range, for these special requirements. To achieve this, the pump is equipped with a position-optimised feed neck which guides the recirculated mass against the direction of flow into the mixing area. This creates turbulences in the biomass which allows an individual blending during feeding. This process is additionally supported by the coupling rod in the blending chamber which is equipped with a screw conveyor. The feeding screw ensures the biomass to be transported into the pump, even in case of high viscosity. The offset segments of the mixing screw and their high thread pitch ensure that more substrate flows to the progressing cavity chambers. The result is an intentional, controlled return flow to create an over feeding, which results in a high efficient homogenisation. Depending on the design, pumps of this type achieve an output of up to 70 m³/h and a pressure of up to 48 bar. The continuous supply to the fermenter which ensures an uninterrupted fermentation process makes it superfluous to use a stronger agitator in the NEMO® B.Max.

NEMO® B.Max progressing cavity pump

  • Medium: Grain waste, corn, gras, chicken manure or slaughterhouse waste
  • Temperature: Up to 80 °C
  • Capacity: Up to 70 m³/h
  • Pressure: Up to 48 bar

You may also be interested in:

Pompa mieszająca NEMO® B.Max

NEMO® B.Max wyznacza nowe standardy poprzez maksymalny stopień sprawności mieszania i przetłaczania biosubstratów

Wersja przemysłowa NEMO® SY ze stojanem łożyskowym i swobodnym czopem końcowym wału

Mimośrodowej pompy ślimakowej NEMO® SY używa się na całym świecie do wymagających zastosowań we wszelkich gałęziach przemysłu. W przypadku wersji ze stojanem łożyskowym i swobodnym czopem końcowym wału pompę można napędzać przy użyciu wszystkich rodzajów napędów

Konstrukcja pompy rotacyjnej TORNADO® T2

Pompa rotacyjna TORNADO® to pompa wyporowa. Tłoczenie zachodzi dzięki obracającym się przeciwbieżnie elementom tłoczącym w obrębie komory (obudowy pompy). Tłoczone medium jest transportowane w obrębie obudowy pompy przez elementy tłoczące od strony ssawnej do strony tłocznej.

Macerator do grubych materiałów M-Ovas®

Rozdrabniacze NETZSCH M-Ovas® znajdują zastosowanie wszędzie tam, gdzie niepożądane w cieczy materiały wymagają niezawodnego rozdrobnienia. Tylko tak można w bezpieczny i niezawodny sposób zapobiec zatykaniu się przewodów i uszkodzeniu podłączonych za ich pomocą urządzeń.