Pumping of Extremely Difficult Media in Oil and Gas Fields:

Progressing Cavity Pumps Convey Oil-Sand Mixtures under Difficult Conditions

Downhole progressing cavity pumps are used in oil and gas fields to pump the most difficult media such as oil-sand mixtures under challenging external conditions.

Despite all efforts to promote renewable energies, global demand for crude oil and natural gas has continued unabated. Methane from coal seams and highly viscous oil at more than 10,000 mPas are already of commercial interest, but are just as complicated to extract. In the Qinshui Basin in China the extraction is as difficult as the extraction of oil sand mixtures from the Sudanese desert where temperatures up to 50°C can be reached.

Look behind the scenes

The traditional image of oil production using pumpjacks with their distinctive 'donkey' heads is still to be seen on many oil fields around the world. The volumetric efficiency of pumpjacks is only around 30 percent and 35 percent for electrical centrifugal submersible pumps. Therefore pumpjacks are increasingly being replaced by a less spectacular, but more efficient system - progressing cavity oil pumps.

Challenge accepted

Highly viscous oils must be conveyed, without pulsation or shear forces, thereby avoiding emulsion effects in oil/water, which would significantly hinder subsequent separation of the oil/water mixtures at the surface.

Excellently solved

The volumetric efficiency of a downhole progressing cavity pump is between 75 and 90 percent. The primary success of this technology is its ability to convey highly viscous oils at above 50,000 mPas while maintaining stable pressure. What is more, it can do so with almost no pulsation or shear forces. As the body of the progressing cavity pump is comparatively slim, it is perfectly suited to the interior of the bore hole. NETZSCH has developed various drive heads for different performance and speed requirements to generate the torque above ground. The standard NTZ model has low life cycle costs thanks to its small number of wearing parts and is suitable for oil mixtures with up to 40 percent gas or sand content at up to 160 °C. It can achieve conveyance rates of between 0.5 and 300 m³/d at maximum 300 bar.

This type of pump is used, for example, to extract methane in coal seams in the Qinshui Basin in China. The water is removed using the progressing cavity pump until the gas is released and can be collected. An additional flow controller was integrated into the control system to avoid running dry.The metal and elastomer materials are selected to match the anticipated conditions for all types of pump to keep wear from the medium to a minimum while simultaneously creating optimal conditions for conveying. Temperature and density are taken into account, as well as the relative content of water, natural gas and hydrogen sulphide. This approach not only increases the performance of the systems, but also ensures a long service life and long maintenance intervals.

NTZ - progressing cavity pump

  • Medium: Oil-mixture
  • Throughput volume: 0.5 up to 475 m³/d
  • Temperature: 160 °C
  • Pressure: Up to 300 bar
  • Viscosity: More than 50.000 cP
As the body of the progressing cavity pump is comparatively slim, it is perfectly suited to the interior of the bore hole.

 

You may also be interested in:

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

The NETZSCH TORNADO® Mobile

A TORNADO® rotary lobe pump fastened onto a mobile base – this is the NETZSCH TORNADO® Mobile. The concept of mounting the equipment onto a car or truck trailer makes it possible to pump large quantities of fluids with solid content, wastewater and slurries at the most unusual of sites.

NEMO® C.Pro Dosing Pump Made of Synthetic Materials

The NEMO® C.Pro dosing pump is a fully synthetic pump for the precise dosing of a great variety of chemicals in environmental technology and the chemical industry. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation conveyance and dosing of aggressive or non-aggressive chemicals.

NEMO® BY Block Pump in Industrial Design

NEMO® BY progressing cavity pumps can be used in any area of industry where a great variety of different substances must be pumped or very precisely dosed.