Brewers from Pennsylvania Counts on Bavarian Pumps:

NEMO® Progressing Cavity Pumps with Open Hopper Convey Abrasive Spent Grains

In 1996 two friends with a passion for brewing premium beer opened the doors to the Brewing Company, a bar, restaurant and brewery in Downingtown, Pennsylvania. From a converted factory building where they brewed 1,725 barrels of beer in their first year.  

Look behind the scenes

More recently the company has opened a second, state-of-the-art brewery in Parkesburg, Pennsylvania. The 19,700 square meter building features a brew house with a production of about 10 brews a day for an annual output of approximately 225,000 barrels. For a brewery with such high demand for its premium beers, the company needs pumping equipment of the highest reliability, maintainability and service life.  

Challenge accepted

Spent grain in the beer brewing process can vary in character, but it is typically hot up to 65°C and can vary widely in moisture levels. It is always abrasive, and significant pressure may need to be generated if the spent grain is to be pumped long distances.    

Excellently solved

NEMO® progressing cavity pumps are designed with elastomer stators which can expand with the heat from the spent grain. To counteract this expansion, the rotor is engineered with a reduced diameter to maximize performance and minimize the torque as it rotates within the stator. In addition a dry run protection was provided with this pump. “To this point, we have done no maintenance on the NETZSCH pump in the Parkesburg brew house. We just let it run. The same NETZSCH pump that conveys spent grain in our Downingtown facility ran for four or five years before the stator needed replacing”, the Vice President accords, even though the spent grain is pumped approximately 250 feet to the spent grain silos outside the brewery.

NETZSCH NEMO® progressing cavity pumps with an inlet hopper

Medium: Spent grain

Throughput: volume  16 m³/h

Rotations speed:  100 up to 150 rpm

Pressure: 5 up tp 18 bar Viscosity 10.000 cPs

Temperature: 65°C


The multipurpose solution

NEMO ® Beverage Pumps find universal use in the wine-growing, wine production, brewery, distillery and beverage production industries. These mobile units provide the flexibility this production environment needs.

NEMO® BO Open Throat Progressing Cavity Pump in Block Construction

The NEMO® BO Progressing Cavity Pump with square/rectangular hopper and coupling rod with auger and force-feed chamber is employed in almost all industrial markets to provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® Barrel Emptying Pumps

NEMO® Barrel Emptying Pumps suction themselves automatically to the bottom of the barrel or container to achieve almost residue-free emptying in the chemical, pharmaceutical and foods industries. The heart of the Barrel Emptying System is a volumetrically conveying NEMO® Progressing Cavity Pump.

NEMO® C.Pro

The NEMO® C.Pro Metering Pump is a fully synthetic pump for the precise metering of a great variety of chemicals in environmental and chemical industries. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation handling and metering of aggressive or non-aggressive chemicals.