Pumping of Extremely Difficult Media in Oil and Gas Fields:

Progressing Cavity Pumps Convey Oil-Sand Mixtures under Difficult Conditions

Despite all efforts to promote renewable energies, global demand for crude oil and natural gas has continued unabated. Methane from coal seams and highly viscous oil at more than 10,000 mPas are already of commercial interest, but are just as complicated to extract. In the Qinshui Basin in China the extraction is as difficult as the extraction of oil sand mixtures from the Sudanese desert where temperatures up to 50°C can be reached.

Look behind the scenes

The traditional image of oil production using pumpjacks with their distinctive 'donkey' heads is still to be seen on many oil fields around the world. The volumetric efficiency of pumpjacks is only around 30 percent and 35 percent for electrical centrifugal submersible pumps. Therefore pumpjacks are increasingly being replaced by a less spectacular, but more efficient system - progressing cavity oil pumps.

Challenge accepted

Highly viscous oils must be conveyed, without pulsation or shear forces, thereby avoiding emulsion effects in oil/water, which would significantly hinder subsequent separation of the oil/water mixtures at the surface.

Excellently solved

The volumetric efficiency of a downhole progressing cavity pump is between 75 and 90 percent. The primary success of this technology is its ability to convey highly viscous oils at above 50,000 mPas while maintaining stable pressure. What is more, it can do so with almost no pulsation or shear forces. As the body of the progressing cavity pump is comparatively slim, it is perfectly suited to the interior of the bore hole. NETZSCH has developed various drive heads for different performance and speed requirements to generate the torque above ground. The standard NTZ model has low life cycle costs thanks to its small number of wearing parts and is suitable for oil mixtures with up to 40 percent gas or sand content at up to 160 °C. It can achieve conveyance rates of between 0.5 and 300 m³/d at maximum 300 bar. This type of pump is used, for example, to extract methane in coal seams in the Qinshui Basin in China. The water is removed using the progressing cavity pump until the gas is released and can be collected. An additional flow controller was integrated into the control system to avoid running dry.The metal and elastomer materials are selected to match the anticipated conditions for all types of pump to keep wear from the medium to a minimum while simultaneously creating optimal conditions for conveying. Temperature and density are taken into account, as well as the relative content of water, natural gas and hydrogen sulphide. This approach not only increases the performance of the systems, but also ensures a long service life and long maintenance intervals.

Technical Data

Technical Data

NETZSCHNTZ - progressing cavity pump
MediumOil-mixture
Throughput volume0.5 up to 475 m³/d
Temperature160°C
PressureUp to 300 bar
Viscositymore than 50.000 cP

More about our Upstream Solutions


Products

Products

TORNADO® Industrial Rotary Lobe Pumps T2

NETZSCH TORNADO® industrial rotary lobe pumps are versatile stand-alone equipment. Used primarily in environmental technology and the chemical industry, these pumps handle almost any substance continuously and gently while metering in proportion to rotation speed.

NEMO® SY Industrial Construction in Bearing Housing Design with Free Shaft Extension

The NEMO® SY Progressing Cavity Pump is used for demanding applications in every branch of industry worldwide. Bearing block with free shaft extension design pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

The NETZSCH TORNADO® Mobile

A TORNADO® rotary lobe pump fastened onto a mobile base – this is the NETZSCH TORNADO® Mobile. The concept of mounting the equipment onto a car or truck trailer makes it possible to pump large quantities of fluids with solid content, wastewater and slurries at the most unusual of sites.

NEMO® C.Pro

The NEMO® C.Pro Metering Pump is a fully synthetic pump for the precise metering of a great variety of chemicals in environmental and chemical industries. Its synthetic construction makes it perfectly suited for the gentle and low-pulsation handling and metering of aggressive or non-aggressive chemicals.

NEMO® BY

NEMO® BY Progressing Cavity Pumps can be used in industrial markets where a great variety of substances must be pumped or very precisely metered.


Literature

Literature