NEMO BO/BS Pump with Hopper in Block Construction

NEMO® BO/BS Pump with Hopper in Block Construction

Ideal pump for crumbly media in compact design for nearly all branches of industry

The NEMO® BO Progressing Cavity Pump with square/rectangular hopper, coupling rod with auger and force-feed chamber is employed in almost all industrial markets to provide continuous, pressure-stable, gentle and low-pulsation conveyance. This special design guarantees better feed into the conveying elements. Another great advantage of the NEMO® Progressing Cavity Pump is its ability to meter nearly any substance in proportion to rotation speed. In block construction with a flanged drive, this pump is particularly compact and economical.

Features of the NEMO® BO Open Throat Progressing Cavity Pump

  • open throat housing with rectangular inlet flange, and auger with force-feed chamber, provides optimal feed for slowly flowing and pasty media into the conveying elements
  • continuous low-pulsation conveyance unaffected by fluctuations in pressure and viscosity
  • capacity in proportion to rotation speed with precision metering over a wide speed range
  • high pressure capability without valves
  • stator with chamfered inlet for optimal filling of the pumping element

 The NEMO® BO Open Throat Progressing Cavity Pump offers you:

  • gentle product handling
  • pump connections in accordance with national and international standards, as well as in specially designed models
  • easy serviceability

Advantages of the NEMO® BO Open Throat Progressing Cavity Pump

  • variable modular system
  • various rotor/stator geometries and a broad array of materials
  • robust and compact block construction
  • the right joint for any application
  • standard mechanical seal, other seals optional
NEMO BO/BS Pump with Hopper in Block Construction

1 Rotor
In wear- and corrosion-resistant designs including the wear-free ceramic rotor NEMO CERATEC®.

2 Stator
Vulcanized into the tube with sealing on both sides in a variety of elastomers, plastics and metals. Stator inlet with chamfered opening for improved feed of the product into the pumping element.

3 Drive Train
Coupling rod with feeding screw and force-feed chamber for improved feed into the conveying elements.  Two universal joints for power transmission from the drive to the rotor.

4 Shaft Seals
Standard with single-acting, bi-directional, wear-resistant mechanical seal. Upon request, with single- or double-acting mechanical seals of varied designs and from various manufacturers, cartridge and special seals as well as packed glands.

5 Suction and Discharge Housing
Pump housing with square/rectangular hopper. The hopper dimensions can be adapted to the individual application.
Flange and threaded connections in accordance with ANSI and NPT and international standards. Materials in cast iron, steel, chrome-nickel-steel rubberized; also special materials upon request.

6 Block Construction
The drive is flanged directly to the pedestal of the pump, resulting in compact dimensions, low total weight.

The NEMO® BO Progressing Cavity Pump is available …

  • in various sizes for flow rates up to 1000 gpm
  • for differential pressures up to 180 psi
  • in various materials, from steel to chrome-nickel-steel to highly acid-resistant materials such as duplex, Hastelloy and titanium
  • with various stator materials like highly abrasion-resistant natural rubber, oil-, acid-, and alkali-resistant elastomers, Aflas and Viton.
  • in S & L Geometry for optimal adjustment to the application
  • with a variety of mechanical shaft seals and packed glands as well as special seals

…and handles

  • highly viscous and crumbly substances that do not have bridge-building tendencies
  • slowly-flowing and non-free-flowing substances with or without suspended solids
Size*

Pressure max.

(bar)

Capacity min.

(m³/h)

Capacity max.

(m³/h)

Speed

(rpm)

NM015 BO/BS

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

up to

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

up to 450

NM021 BO/BS
NM031 BO/BS
NM038 BO/BS
NM045 BO/BS
NM053 BO/BS
NM063 BO/BS
NM076 BO/BS
NM090 BO/BS
NM105 BO/BS
NM125 BO/BS

*Further sizes and technical data on request.

  • Variable modular system
  • Various rotor/stator geometries and a large spectrum of materials
  • Robust and compact block construction
  • The right joint for any application
  • Standard mechanical seal, other seals optional
  • Gentle product conveyance
  • Pump connections in accordance with national and international standards, as well as in specially designed models
  • Easy serviceability

You may also be interested in:

NEMO® BF Open Throat Progressing Cavity Pump with Auger

The NEMO® BF is used in all industrial markets to provide continuous, pressure-stable, gentle and low-pulsation handling with metering in proportion to rotation speed. This pump is used primarily for highly viscous, compacted and crumbly substances that do not have a tendency to bridge.

NEMO® BF Hopper-Shaped Progressing Cavity Pump With aBP-Module®

The NEMO® BF hopper-shaped progressing cavity pump with aBP-Module® to prevent bridging is used in all branches of industry for continuous, pressure-stable, gentle and low-pulsation conveyance as well as dosing in proportion to speed, especially for highly viscous, compacted and crumbly media.

NEMO® BO/SO Hopper Pump With Integrated Cutting Device

The NEMO® BO/SO progressing cavity pump with hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to  provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.