NEMO® BT Immersible Pumps With Bracket or Flanges

The ideal solution for emptying containers, sewage tanks or pits in confined spaces

NEMO® immersible pumps are used to empty barrels, containers, tanks, sedimentation tanks, pits etc. and where space is restricted, there is a risk of cavitation or there is very low NPSH.

The pumps are also used to empty containers holding materials that are hazardous to water or the environment for which standard emptying via a flange on the bottom of the container is not permitted. Features of the NEMO® BT immersible pump:

  • Low-pulsation conveyance
  • Very high suction capability

NEMO® BT immersible pump offers you:

  • Low life cycle costs
  • Easy serviceability
  • Perfect dosing precision

Advantages of the NEMO® BT immersible pump:

  • Can be operated under high conveying pressures and at high capacities
  • Capable of pumping a great variety of substances
  • Capacities can be adjusted proportionally
  • Four different geometries to meet your application requirements

1 Rotor
In wear- and corrosion-resistant designs, even as wear free ceramic rotor NEMO CERATEC®.

2 Stator
Vulcanized into the tube with sealing on both sides in a variety of elastomers, plastics and metals. Stator inlet with hopper-shaped opening for improved feed of the product into the conveying chamber. The stator is oil-, acid- and alkali-resistant.

3 Drive chain
Coupling rod and two gimbal joints for the transmission of power from the drive to the rotor.

4 Shaft seals
Standard with single-acting, bi-directional, wear-resistant mechanical seal. Upon request, with single- or double-acting mechanical seals in various designs and from various manufacturers, cartridge and special seals as well as packed glands.

5 Suction and discharge housing
Flange and threaded connections in accordance with DIN and international standards. Materials in cast iron, steel, chrome-nickel-steel rubberized; special materials upon request.

6 Block construction
The drive is flanged directly to the lantern of the pump, resulting in compact dimensions, low total weight, constant axial heights irrespective of the construction type and size of the drive, and ease of maintenance and serviceability as well as high efficiency.

NEMO® BT immersible pumps with dome cover flange are used for low-pulsation emptying of closed barrels and similar containers.
Size*

Pressure max.

(bar)

Capacity min.

(m³/h)

Capacity max.

(m³/h)

Speed

(rpm)

NM021 BT

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

up to

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

up to 600

NM031 BT
NM038 BT
NM045 BT
NM053 BT
NM063 BT
NM076 BT
NM090 BT
NM105 BT

*Further sizes and technical data on request.

  • Can be operated under high conveying pressures and at high capacities
  • Capable of pumping a great variety of substances
  • Capacities can be adjusted proportionally
  • Four different geometries to meet your application requirements
  • Low life cycle costs
  • Easy serviceability
  • Perfect dosing precision

You may be also interested:

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.

NEMO® BY

NEMO® BY Progressing Cavity Pumps can be used in industrial markets where a great variety of substances must be pumped or very precisely metered.

Barrel Emptying System with NEMO® BY Pump

NEMO® barrel emptying pumps suction themselves automatically to the bottom of the barrel or container to achieve almost residue-free emptying in the chemical, pharmaceutical and foods industries. 

NEMO® SY Industrial Construction in Bearing Housing Design with Free Shaft Extension

The NEMO® SY Progressing Cavity Pump is used for demanding applications in every branch of industry worldwide. Bearing block with free shaft extension design pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.


Brochure

Comprehensive and uncompromising solutions for all industries.

Brochure

NEMO® BT Pump models provide a variety of mounting options.