NEMO® BF with feeding screw and aBP-Module®

NEMO® BF Hopper-Shaped Pump With aBP-Module®

The solution for highly viscous and crumbly substances that tend to bridge

The NEMO® BF hopper-shaped progressing cavity pump with aBP-Module® to prevent bridging is used in all branches of industry for continuous, pressure-stable, gentle and low-pulsation conveyance as well as dosing in proportion to speed, especially for highly viscous, compacted and crumbly media.

For optimum product feed into the conveying elements, the pump housing is designed with an enlarged, rectangular feed hopper and conical force-feed chamber as well as a special coupling rod with patented, positioned conveying screw. The additionally attached aBP-Module® - asynchronous Bridge Preventing - consists of a top shaft with two internal spoke wheels. These create "moving shaft walls" which exert a shearing effect on the medium. This reliably prevents bridge formation in the pump shaft.  This also ensures the smooth conveying of solid-loaden, shear-sensitive, abrasive, adhesive, thixotropic or dilatant as well as lubricating and non-lubricating materials that have a tendency to bridge. The NEMO® is particularly compact and economical in block construction with flanged drive.

Get a personalized offer now!

NEMO® BF Hopper-Shaped Pump with aBP-Module®

1 Rotor
In wear- and corrosion-resistant designs.

2 Stator
Vulcanized into the tube with sealing on both sides in a variety of elastomers, plastics and metals. Stator inlet with hopper-shaped opening for improved feed of the product into the conveying chamber.

3 Drive chain
Drive and connecting shaft with a coupling rod with patented, horizontally positioned feeding screw for optimal feed into the conveying elements and two gimbal joints for the transmission of power from the drive to the rotor.

4 Shaft seals
Standard with single-acting, bi-directional, wear-resistant mechanical seal. Upon request, with single- or double-acting mechanical seals of varied designs and from various manufacturers, cartridge and special seals as well as packed glands.

5 Suction and discharge housing
Pump housing with enlarged rectangular hopper and conical force-feed chamber. The hopper dimensions can be adjusted to the individual application case. Flange and threaded connections in accordance with DIN and international standards. Materials in steel, chrome-nickel-steel rubberized; also special materials upon request.

6 Block construction
The drive is flanged directly to the lantern of the pump, resulting in compact dimensions, low total weight, constant axial heights irrespective of the construction type and size of the drive, and ease of maintenance and serviceability as well as high efficiency.

Size*

Capacity min.

(gpm)

Capacity min.

(m³/h)

Capacity max.

(gpm)

Capacity max.

(m³/h)

Max. pressure

(psi)

Max. Pressure

(bar)

Speed

(rpm)

NM045 BF

1.9

0.4

29

7

720

48

300

NM053 BF 3.3 0.7 49 11 720 48 300
NM063 BF 5.5 1.2 82 19 720 48 300
NM076 BF 9.2 2.1 138 31 720 48 300
NM090 BF 15.5 3.5 232 53 720 48 300
NM105 BF 25.9 5.9 389 88 720 48 300

*Additional sizes and technical data on request.

  • No bridging
  • Ideal adaptation of the differential speed of the spoked wheels to the respective fluid
  • Pump connections according to national and international standards, as well as in special design
  • Easy serviceability
  • Variable, modular construction system
  • Wide range of materials
  • Robust and compact block design
  • The right joint for every application
  • Mechanical seal as standard, other seals optional

You may be also interested:

NEMO® BO Open Throat Progressing Cavity Pump in Block Construction

The NEMO® BO Progressing Cavity Pump with square/rectangular hopper and coupling rod with auger and force-feed chamber is employed in almost all industrial markets to provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® BF Open Throat Progressing Cavity Pump with Auger

The NEMO® BF is used in all industrial markets to provide continuous, pressure-stable, gentle and low-pulsation handling with metering in proportion to rotation speed. This pump is used primarily for highly viscous, compacted and crumbly substances that do not have a tendency to bridge.

NEMO® B.Max Mixing Pump

The NEMO® B.Max is setting new standards with its maximum mixing and conveying capabilities for biosubstrates.

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.


Brochure

Continuous product feeding without bridging

Brochure

Comprehensive and uncompromising solutions for all industries.