The NEMO® SH Plus Sanitary Pump is employed for sanitary applications in the food products, pharmaceutical, cosmetic and chemical/biochemical industries to provide continuous, pressure-stable, gentle and low-pulsation conveyance with optimal cleaning and metering in proportion to speed.
The design with bearing housing and free shaft ends enables allows you to select any drive type.
Various regulatory agencies have set specifications for a sanitary configuration of components and machines, as well as for component cleanability. NEMO PUMPS® are designed, produced and inspected in accordance with the regulations of the EHEDG (European Hygienic Equipment Design Group) and the QHD (Qualified Hygienic Design). The materials used are approved by the FDA (Food and Drug Administration). In addition, NEMO® Sanitary and Aseptic Eccentric Screw Pumps meet the 3-A Sanitary Standards specifications of the United States and are GOST-R certified (a Russian certificate of conformity).
Features of the NEMO® SH Plus Sanitary Pumps
- continuous low-pulsation pumping unaffected by fluctuations in pressure and viscosity
- capacity in proportion to rotation speed with precision metering over a broad speed range
- high suction and pressure capability without valves
- reversible pumping direction
- stator with conically-shaped entrance for optimal filling of the pumping chamber
NEMO® SH Plus Sanitary Pumps offer you:
- flexible rod design for uncompromising hygiene and long service life
- gentle product conveyance
- long production cycles with contamination-proof, sterile pump construction
- CIP and SIP capability
- product admission under vacuum conditions up to almost an absolute vacuum
- open, patented sanitary joints for sticky substances
- elastomers approved for food products in accordance with FDA and BfR
- horizontal and vertical installation
- easy serviceability
Advantages of the NEMO® SH Plus Sanitary Pump:
- food-suitable shaft seals, with compression-proof bolted seal casing, enable reversal of rotational direction and thereby also of the direction of pumping, up to the maximum pump pressure
- streamlined, crevice-free housing model prevents sedimentation of the product
- all product-contacting surfaces are polished to prevent build-up of the product and facilitate to cleaning
- the pump housing and stator can be optionally heated
Take advantage of our decades of experience and expertise in positive displacement pump manufacture.
Your edge – process stability even under great demands!
1 Rotor
In two geometries and with polished surfaces.
2 Stator with Reduced Walls
For changing temperatures, a patented stator with reduced elastomer wall thickness is used. In addition, a thermal stator protector (STP) provides protection against overheating and dry running. The stator inlet has a conically-shaped opening for improved feed into the pumping element.
3 Drive Train
The all-purpose flexible rod used for the transfer of power from the drive to the rotor in the NEMO® SH Plus Sanitary Pump is corrosion-resistant as well as dead-space, wear- and maintenance-free, because no components move against each other as they do in joints. Neither lubricants nor seals are needed, so the lubricating properties of the pumped product need not even be taken into account. This is ideal for sensitive substances with or without suspended solids and for uncompromising cleanliness.
4 Seal Casing
Shaft seals suitable for contact with food products, with compression-proof, bolted shaft seal housing, enable a reversal of the direction of rotation up to the maximum pumping pressure.
5 Protective Tubing for Stator
Made of stainless steel (optional)
6 With Bearing Block and Free Shaft Ends
The design with bearing block and free shaft ends enables the universal employment of any drive type.
The NEMO® SH Plus Sanitary Pump is available …
- in various sizes for flow rates up to 620 gpm
- for differential pressures up to 350 psi
- with optional tangential CIP supports on the pump housing and end supports
- with stators and gaskets with various elastomers approved for contact with food products
- with stators with reduced walls
- with S & L Geometry for optimal adjustment to the application
… handles…
- sensitive substances under gentle, hygienic conditions
… and offers
- a variety of shaft seals and construction types
CIP/SIP Process
To achieve the velocity of flow necessary for the cleaning fluid of at least 5 ft/s in the entire system in accordance with CIP procedures, NEMO® Sanitary and Aseptic Progressing Cavity Pumps are equipped with additional flushing supports in tangential configuration and must be equipped with a bypass line. The bypass is also necessary for the SIP process. The NEMO® Pump operates in a synchronized fashion both for the CIP and for the SIP process.
With tangential flushing supports, complete evacuation of the NEMO® pump is guaranteed. All pump materials are suitable for CIP and SIP processes.
Universally applicable – the NEMO® SH Plus Sanitary Pump
The NEMO® SH Plus Sanitary Pump is employed for sanitary applications in the food products, pharmaceutical, cosmetic and chemical/biochemical industries to provide continuous, pressure-stable, gentle and low-pulsation pumping with optimal cleaning and metering in proportion to speed. The flexible rod makes this pump ideal for sensitive substances – with or without suspended solids – when uncompromising cleanliness is a must.
Wide Range of Applications
The NEMO® SH Plus Sanitary Pump is used primarily for substances with the following properties:
- shear-sensitive
- low to very high viscosity
- sticky to dry
- substances with or without solid content
- thixotropic and dilatant
- abrasive
- adhesive
… such as
yeast, cream, mustard, mayonnaise, yogurt, soft cheeses, ointments, chunky sauces, eggs, milk, curd cheeses, honey, marmalade, syrup, ketchup, sourdough and many others.
Additional Features
- high suction capability of up to 29 ftWC
- bi-directional
- vertical or horizontal installation
- low noise, low vibration
Wide Range of Capacities and Pressures
- adjustable capacities up to 620 gpm
- for differential pressures up to 350 psi
The following accessories are available for the NEMO® SH Plus Sanitary Pump:
- dry running protection units for NEMOLAST® stators
- flow sensing unit for solid stators
- speed monitoring device
- diaphragm pressure gauges with various connections
- multi-function pressure instrument
- quench pot
- pressurized flushing for double mechanical seal systems
- anchor bolts
- stator removal tool
- adjustable feet
- mobile and trailer mounted units
- covers for drives