M-Ovas® Universal Cutting Plate Macerator

耐驰M-Ovas®切碎机

普遍应用

耐驰M-Ovas®研磨系统可在任何液体中的固体物料发生断裂的情况下使用,以防止管道堵塞或损毁下游设备。 特别设计的M-Ovas®切碎机腔体可将废水中固体物料输送至切刀盘,再由其上旋转刀片将固体物料固定住并将其切碎。该低维护成本装配专为最大流量为 300 m3/h 并含有高达 7% 干固体物的污水而设计。

耐驰M-Ovas®切碎机的优势:

  • 由于其结构坚固,因此具有高度运行安全性
  • 易于操作,维护简单
  • 工作效率高,因此运行费用低
  • 最佳性价比/性能比

 

耐驰M-Ovas®切碎机主要应用于以下领域:

  • 废水处理
  • 农业
  • 屠宰场与废物回收厂
  • 罐头/罐头包装厂
  • 制糖厂
  • 工业配料室
M-Ovas® Universal Cutting Plate Macerator

1 Housing
Hydrodynamic design with integrated stone trap for solids, and a clean-out port. The sediment can easily be removed by opening the cover plate. The housing is galvanized to ensure corrosion resistance. Available in stainless steel (optional).

2 Housing cover
Cutting unit integrated into housing cover. A gas strut is fitted to the cover to assist opening.

3 Cutting unit
The cutting plate is made of wear resistant, hardened steel. Optimum cutting performance through cutting unit with a fixed cutting mechanism. Cutting head and cutting blades made from wear resistant hardened steel. The flywheel effect of the cutting head supports the cutting process and reduces the drive power. Easy exchange of cutting plate and cutting blades without disassembling the pipework. A manual adjustment is not necessary due to the pressure spring support.

4 Shaft seal
Single mechanical seal made of hard metal with oil quench to prevent product leakage.

5 Drive
The standard drive unit has reinforced bearings.

6 Inline version
Product inlet and outlet are positioned on the same level. The M-Ovas® can be directly connected to a horizontal pipeline or to a pump inlet where the flange is set at 90°.

Size*

Flow rate

(m3/h)

Pressure drop

(bar)

Maximum pressure

(bar)

Approximate weight

(kg)

S 2,2/50 50 0.05 1 120
S 4,0/300 300 0.12 1 195

*Further sizes and technical data on request.

  • Protects the system from large solids and possible consequential damage
  • High cutting efficiency avoids clogging by materials such as fabric remnants or long fibres
  • Compact design with high throughput
  • Easy and quick removal of the cutting plate, saves time and costs
  • Low energy consumption at high throughput rates
  • Integrated clean-out port with separate cleaning and drain opening
  • Shaft sealed by mechanical seal with grease lubrication
  • Particularly maintenance-friendly, no removal from the pipeline necessary
  • Cutting plate can be used on both sides
  • Different perforated plates depending on the application

You may be also interested:

N.Mac® 平行轴强力切碎机

可破碎大的固体颗粒,N.Mac®平行轴式强力切碎机是您各种应用中理想的选择

N.Mac® Inline Twin Shaft Grinder

The N.Mac® inline twin shaft grinder crushes fragmenting large and solid particles in liquid media and impresses with its FSIP® concept (Full Service in Place).

NEMO® BO/SO Hopper Pump With Integrated Cutting Device

The NEMO® BO/SO progressing cavity pump with hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to  provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.