N.Mac® Channel Twin Shaft Grinder

N.Mac®平行轴强力切碎机

适合各种应用的理想设备

可破碎大的固体颗粒,N.Mac®平行轴式强力切碎机是您各种应用中理想的选择。例如:污水处理、沼气工程、食品和果汁残渣。管道式及渠道式两种形式的腔室设计污水管道设计可以通过法兰式联接直接和泵相连以防止管道堵塞,保护下游设备;如:各种泵

 

 

 

 

 

N.Mac® Channel Twin Shaft Grinder

1 Housing
Housing for channel installation to protect against blockage and damage to following devices.

2 Cutting unit
There are different cutting blocks with special geometry for optimum crushing of the solids. To achieve the desired size reduction result, the different knife configurations with three to eleven teeth can be combined with each other. Knife configuration with seven teeth as standard. The cutting tools are hardened to increase impact resistance and sharpness, so that even the most difficult of contaminants can be shredded reliably.

3 Shaft seal
Mechanical seal with quench and patented bearing and mechanical seal cartridges.

4 Drive
Energy-efficient motors with 2.2 kW, 3 kW or 4 kW are installed as standard. These offer optional control with reversal of direction of rotation for protection in the event of blockages.

5 Channel version
Product inlet and outlet are at the same height. An extended shaft is optionally available so that the motor can be installed above the medium.

Size*

Flow rate

(m³/h)

Approximate weight

(kg)

N.Mac® 50C 50 170
N.Mac® 120C 120 200
N.Mac® 250C 250 260
N.Mac® 400C 400 320

*Further sizes and technical data on request.

  • Protects the system from damage caused by contaminants
  • Anti-vibration system: Exclusive elastomer to seal the lower bearings and absorb vibrations generated during shredding
  • Bearing and mechanical seal cartridges to protect the bearings
  • Optional cleaning brush for fibrous materials removes material in the gaps between the blades
  • Cutting devices in the cartridge system
  • Modular design of the cutter blocks allows individual combinations
  • Easy on-site maintenance thanks to innovative FSIP® design
  • Optional extended shaft for channel designs that allows the motor to be installed above the medium
  • Retractable suspension lugs to facilitate disassembly

You may be also interested:

耐驰M-Ovas®切碎机

耐驰M-Ovas®切碎机可在任何液体中的固体物料发生断裂的情况下使用,以防止管道堵塞或损毁下游设备。

N.Mac® Inline Twin Shaft Grinder

The N.Mac® inline twin shaft grinder crushes fragmenting large and solid particles in liquid media and impresses with its FSIP® concept (Full Service in Place).

NEMO® BO/SO Hopper Pump With Integrated Cutting Device

The NEMO® BO/SO progressing cavity pump with hopper and coupling rod with feeding screw and force-feed chamber is employed in almost all branches of industry to  provide continuous, pressure-stable, gentle and low-pulsation conveyance.

NEMO® Progressing Cavity Pump in FSIP® Design

The FSIP® concept of the NEMO® progressing cavity pump is especially interesting where pumps are installed in wear intensive applications.