Processing Various Substrates into Biogas:

NEMO® Progressing Cavity Pumps Process Everything from Liquid Manure to Waste

The space-saving NEMO® progressing cavity pumps convey a wide variety of substrates during the production of biogas without major maintenance work or breakdowns.

In addition, the pumps are distinguished by their long service life.

Look behind the scenes

This example follows Agrivalor Énergie in Alsace, which feeds its cogeneration plant with biogas from leftover food production and food that has passed its sell-by-date. Mixtures from maize silage, liquid manure, and grape marc, but also food waste from restaurants, schools and supermarkets are conveyed into a mixing tank from where they travel on to the fermenter, where the biogas is formed.  

Challenge accepted

However, the varying mixtures of materials put a major strain on the plant’s conveying systems. Some of the materials, such as the liquid manure, are corrosive and some are fibrous and likely to cause obstructions, such as grain waste. Materials of animal origin also have to be exposed to intense heat to prevent disease, so some media are still at 70 or 80°C when they are conveyed.  

Excellently solved

Agrivalor Énergie ordered ten NETZSCH-made NEMO® progressing cavity pumps to achieve maximum possible reliability without significant maintenance or downtimes, despite the tough conditions. Two of the larger pumps with capacities of around 40 m³/h are used to transport the mixture from the collecting tank (with around six to seven percent dry matter content) into the fermenter. Other NEMO® pumps with a capacity of 20 m³/h are used to convey the recirculated substance and introduce the sanitised hot liquid manure into the mixer. All the units are extremely compact and have a block design with flange-mounted motor, saving a lot of space on the premises of the privately owned biogas plant. The efficient pump design only requires minimal power, which – along with the long service life and long maintenance intervals – leads to low overall operating costs.

Get an individual offer for your application now!

NEMO® progressing cavity pump

  • Medium: maize silage, liquid manure, grape marc, food waste, fats and dairy products
  • Temperature: 70 up to 80 °C
  • Conveying capacity: 20 up to 40 m³/h

You may also be interested in:

NEMO® B.Max Mixing Pump in Block Design

The NEMO® B.Max is setting new standards with its maximum mixing and conveying capabilities for biosubstrates.

NEMO® SY Industrial Construction in Bearing Block Design

The NEMO® SY progressing cavity pump is used for demanding applications in every branch of industry around the globe. In bearing block design with free shaft extension, this pump can be run with any type of drive, such as servo motors, diesel motors or hydraulic drives.

TORNADO® T2 Industrial Rotary Lobe Pumps

The TORNADO® T2 rotary lobe pump is a positive displacement pump. The pumping action is generated by the contra-rotation of two rotors within the pump chamber which are synchronised externally. The media enters the pump chamber through the inlet port and is carried around the chamber by the rotors to the outlet port where it is discharged.

M-Ovas® Grinding System

NETZSCH M-Ovas® grinding systems can be used wherever it is essential that solid matter in fluids be broken down reliably to ensure the prevention of pipe clogging and damage to downstream equipment.